Planet ICA-4500V User Manual

Planet ICA-4500V User Manual

5 mp 20m ir vari-focal dome ip camera
Hide thumbs Also See for ICA-4500V:
Table of Contents

Advertisement

Quick Links

5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera
ICA-4500V
5 Mega-Pixel 20M IR
Vari-Focal Dome IP Camera
ICA-4500V

Advertisement

Table of Contents
loading

Summary of Contents for Planet ICA-4500V

  • Page 1 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V...
  • Page 2 ICA-4500V Copyright Copyright © 2013 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of PLANET.
  • Page 3 Do not dispose of WEEE as unsorted municipal waste; they should be collected separately. Revision User’s Manual for PLANET 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera Model: ICA-4500V Rev: 1.00 (February.2013) Part No. EM-ICA4500V...
  • Page 4: Table Of Contents

    2.3 Initial Utility Installation ................... 21   2.4 Preparation ....................... 23   2.4.1 Search and View by PLANET IP Wizard II........23   2.4.2 Configure Network by PLANET IP Wizard II........25   2.5 Using UPnP of Windows XP or 7 ..............26  ...
  • Page 5 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.6.1 Picture ....................53   3.6.2 Privacy Mask..................55   3.6.3 PTZ Setting ................... 56   3.6.4 Preset Setting ..................57   3.6.5 Tour Setting ................... 58   3.7 System....................... 59  ...
  • Page 6: Chapter 1. Product Introduction

    1.2. Overview Exceptional Surveillance with Vari Focal 5 Mega-Pixel Camera PLANET ICA-4500V Network Camera with IR Illuminator is a high resolution camera for round-the-clock surveillance over IP networks. It supports H.264, MPEG-4, and JPEG compression formats and delivers excellent picture quality in 5 mega-pixel resolutions at 15 frames per second (fps) and Full HD resolutions at 30 fps.
  • Page 7 To adapt to constantly changing lighting conditions, the ICA-4500V comes with a removable IR-Cut filter and built-in IR illuminators, which enable the camera to provide color video when there is sufficient light, and black/white video in dark conditions. The ICA-4500V is able to maintain clear images 24 hours a day.
  • Page 8 When people pass by or in an emergency situation, the built-in PIR motion detection sensor in the ICA-4500V will “detect” and start recording automatically. It is able to detect movement far from 6 meters away. When motion is detected in the specified areas, the additional function of alarm notification can send an e-mail alert or send captured images via FTP upload to a designated storage server.
  • Page 9 Flexible Installation and Power Functionality The ICA-4500V incorporates IEEE 802.3af Power over Ethernet standard and able to be powered via the network cable from a PoE power sourcing equipment such as PoE Switch and PoE injector.
  • Page 10: Features

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 1.3. Features Camera 1/3 type 5MP CMOS sensor 3.3~12.0 mm Vari-Focal, DC Auto-Iris Lens 0.5 lux Minimum Illumination at F1.4 Maximum Resolution of 2592x1944 Removable IR-Cut Filter for Day & Night Function...
  • Page 11 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Effective Pixels 1920 x 1080 pixels Image Video Compression H.264 / MPEG-4 / M-JPEG 5M mode H.264: 2592 x 1944 / 1280 x 960 / 640 x 480 / 320 x 240...
  • Page 12 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V External output activation Audio alerting output Go to PTZ preset position Video Buffer Pre- and post-alarm buffering General 12V DC, 1A Power Requirements IEEE 802.3af Class 3 Power Consumption 8W max.
  • Page 13: Chapter 2. Hardware Interface

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Chapter 2. Hardware Interface 2.1 Physical Descriptions 2.1.1 Identification of ICA-4500V physical details Item Description Lens Keep lens clean to keep excellent video quality. IR LED Emits infrared light to provide light source in dark places Detects the illumination level or the place where this IP camera is installed, and switches IR LEDs on when it’s required.
  • Page 14: I/O Control Instruction

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 2.1.2 I/O Control Instruction Descriptions for I/O cable set: Interface Description The input power is DC 12V, 1A. DC Power ONLY use package power adapter supplied with the internet. Otherwise, the product may be damaged.
  • Page 15 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Reset This button is used to restore all the factory default settings. (Factory Default) The 6 pin terminal block includes 1 input port and 1 output port, and RS-485 D+ and D-.
  • Page 16: Connector Board

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 2.1.3 Connector board Terminal Block Pin12 Factory Pin1  Default Micro SD Reset Card Slot 12VDC in (red) Video out 1  2  Audio in/out (red) Reset & LAN LED DIDO+ RS485 6 ...
  • Page 17 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Connect to PC or Hub/Switch. For connecting to 10Base-T Ethernet or 100Base-TX or 1000Base-T Fast Ethernet / Gigabit Ethernet cabling. This Ethernet port built auto-negotiation protocol can detect or negotiate the transmission speed of the network automatically.
  • Page 18: Hardware Installation

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 2.2 Hardware Installation 2.2.1 Connector board 1. Please select the most suitable position on ceiling to install the camera. 2. Remove two screws to release the top cover of the dome and open it.
  • Page 19: Network Installation

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 5. Connect the LAN cable to Ethernet’s switch or hub and the DC-Jack to the power source. Use the power adapter, 12VDC, included in the package and connect it to wall outlet for AC power.
  • Page 20 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 4. Attach Speaker to camera (optional) If user needs not only video stream but also audio stream, then the speaker should be attached to camera. 5. PoE (Power over Ethernet) Power over Ethernet (PoE) is a technology that integrates power into a standard LAN infrastructure.
  • Page 21: Initial Utility Installation

    If the welcome screen does not appear, click “Start” at the taskbar. Then, select “Run” and type “D:\Utility\IPWizard II\setup.exe”, assume D is your CD-ROM drive. 3. The “Welcome to the Install Shield Wizard for PLANET IP Wizard II” prompt will display on the screen and click “Next” to continue.
  • Page 22 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 5. Please click “Install” to start the installation. Please click “Finish” to complete the installation and launch program immediately.
  • Page 23: Preparation

    When you install the Internet Camera on a LAN environment, you have two easy ways to search your cameras by PLANET IP Wizard II or UPnP discovery. Here is the way to execute PLANET IP Wizard II to discover camera’s IP address and set up related parameter in a camera.
  • Page 24 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V When launching the Planet IP Wizard II, a search windows will pop up. Planet IP Wizard II is starting to search Internet Cameras on the LAN. The existed devices will be listed as below.
  • Page 25: Configure Network By Planet Ip Wizard Ii

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 2.4.2 Configure Network by PLANET IP Wizard II In case you want to change the IP related parameters of wired interface, please select the Internet Camera you want to configure and click the LAN button. Relative settings will be carried out as below.
  • Page 26: Using Upnp Of Windows Xp Or 7

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V “<<” perform your setting accordingly. Click button will go back to the previous page. If you like to change username and/or password of the device, just click the check button. Then, the related fields will show up as below.
  • Page 27 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V The “Control Panel” will display on the screen and double click “Add or Remove Programs” to continue. The “Add or Remove Programs” will display on the screen and click Add/Remove Widows...
  • Page 28 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V The following screen will appear, select “Networking Services” and click “Details” to continue. The “Networking Services” will display on the screen, select “Universal Plug and Play” and click “OK” to continue.
  • Page 29 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V The program will start installing the UPnP automatically. You will see the below pop-up screen, please wait while Setup configures the components. Please click “Finish” to complete the UPnP installation...
  • Page 30: Windows 7

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Double-click “My Network Places” on the desktop, the “My Network Places” will display on the screen and double-click the UPnP icon with Internet Came ra to view your device in an internet browser.
  • Page 31 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V...
  • Page 32: Setup Activex To Use The Internet Camera

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V ICA-4500V 2.6 Setup ActiveX to use the Internet Camera The Internet Camera web pages communicate with the Internet Camera using an ActiveX control.
  • Page 33: Internet Explorer 7 For Windows Xp

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V By now, you have finished your entire PC configuration for Internet Camera. 2.6.2 Internet Explorer 7 for Windows XP From your IE browse ”Tools” ”Internet Options…” ”Security” ”Custom Level…”, please set up your “Settings” as follows: Set the first 3 items •...
  • Page 34: Internet Explorer 7 For Windows Vista

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V By now, you have finished your entire PC configuration for Internet Camera. 2.6.3 Internet Explorer 7 for Windows Vista From your IE browse ”Tools” ”Internet Options…” ”Security” ”Internet” ”Custom Level…”, please set up your “Settings” as follows: •...
  • Page 35 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V By now, you have finished your entire PC configuration for Internet Camera.
  • Page 36: Chapter 3. Web-Based Management

    The Default IP: “http://192.168.0.20“ The login window of Internet Camera will appear, Default login username and password is: admin admin If the User Name and Password have been changed with PLANET IP Wizard II, please enter the new User Name and Password here.
  • Page 37 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V After logged on, you should see the following messages at the top of Internet Explorer: Click on the message, and click Run Add-on When you see this message, click Run’ to install required ActiveX control After the ActiveX control is installed and run, the first image will be displayed.
  • Page 38: Live View

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.3 Live View Start-up screen will be as follows no matter you are an ordinary user or an administrator. Video Profile ActiveX Control Streaming Protocol Language Monitor Image Section Setting Menu...
  • Page 39 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V This feature only supports the ActiveX control within Microsoft® Internet Explorer. Setting Menu This function is a detailed setting of the camera that is only available for administrator to enable to log-in camera.
  • Page 40: Activex Control

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Information rate and bit rate. 3.4 ActiveX Control The plug-in ActiveX control supports a lot of functions by clicking the left mouse button. This feature only supports the ActiveX control within Microsoft® Internet Explorer.
  • Page 41: Digital Zoom

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.4.1 Digital Zoom Click Digital Zoom to activate this function as above. User can drag or scale the box over the video to adjust zoom ratio and position. 3.4.2 Snapshot Click Snapshot to activate this function. Press Snapshot button to take a picture. The image file is saved as JPEG format into your local PC.
  • Page 42: Volume

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V After stopping recording, list the file. This file is named as Video_yyyymmddhhmmss.asf The ASF files can be displayed by the standard Windows Media Player, but it needs the DixectX 9.0 or later version to be installed.
  • Page 43: Network

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.5 Network Use this menu to configure the network to connect the device and the clients. 3.5.1 Network This section provides the menu of connecting the device through Ethernet cable. Display the Ethernet MAC address of the device. Note that user cannot MAC address change it.
  • Page 44 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V separated by periods, for example: 192.168.0.200 Subnets allow network traffic between hosts to be separated based on the network's configuration. In IP networking, traffic takes the form of packets. IP subnets advance network security and performance to some level by organizing hosts into logical groups.
  • Page 45: Ipv6

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V If you log in the camera as an ordinary user, setting function will be not available. If you log in the camera as an administrator, you can perform all the settings provided within the device.
  • Page 46: Ddns Server

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V To enable or disable the HTTPS service here. Note that the HTTPS HTTPS function of this device is not only encrypted the web content but also audio/video data. Port Choose the HTTPS port. The default value is 443.
  • Page 47: Pppoe

    The user name is used to log into DDNS. Password The password is used to log into DDNS. This model adds Planet easy DDNS that when this function enable will occur hostname with PLANET DDNS and end six of MAC automatically. User don’t go to web of www.planetddns.com apply new account.
  • Page 48: Streaming

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V the PPPoE information first, and then connect to the xDSL modem. Power on again, then the device will dial on to the ISP connect to the WAN through the xDSL modem.
  • Page 49: Upnp

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Choose the RTSP port. The RTSP protocol allows a connecting client to RTSP Port start a video stream. Enter the RTSP port number to use. The default value is 554. Specify the range of transmission port number of video stream. The default RTP Port range is 50000 to 50999.
  • Page 50: Bonjour

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V traversal when your device is located on an intranet (LAN) and you wish to make it available from the other (WAN) side of a NAT router. With NAT traversal properly configured, all HTTP traffic to an external HTTP port in the NAT router will be forwarded to the device.
  • Page 51: Ip Filter

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.5.9 IP Filter You can enter different user IP addresses which are allowed to enter or deny by the device. IP Filter To enable or disable the IP filter function here.
  • Page 52: Camera

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V If this function is enabled, the “Send to“ and “Subject” field SMTP Notification (e-mail) need to be filled. Type the receiver’s e-mail address. This address is used for Send To reply mail.
  • Page 53: Picture

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.6.1 Picture Turn the “Mirror” and “Vertical Flip” On or OFF. The image will be overturned as below. Rotation Auto: will adjust the white balance automatically. White Balance Hold: will hold the white balance.
  • Page 54 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Hold Exposure: will hold the internal gain. Auto Iris: This Camera is built-in a DC-Iris lens. User can choose the Iris control mode from “Auto” or “Off”. In case, the “Auto” mode is selected, the Camera will control DC Iris automatically.
  • Page 55: Privacy Mask

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V In case user selects manual mode, there are 4 modes: Night (On), Day (Off), Auto or Schedule to control built-in IR LEDs. This function is very useful under low illumination environment even 0 Lux.
  • Page 56: Ptz Setting

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V To add or delete the privacy mask windows, user can specify up to 7 windows to mask the video captured by this device. By dragging Add and Delete mouse on the image, you can change the position and size of the selected window accordingly.
  • Page 57: Preset Setting

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V This device can connect to a PTZ camera or speed dome camera and Camera Protocol controls them through RS-485 interface. This is the camera ID set in PTZ camera or speed dome camera.
  • Page 58: Tour Setting

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.6.5 Tour Setting Up to 64 positions can be preset, and the camera can be programmed to move to the preset position sequentially. The group name of the sequence of camera tour. The maximum number of Tour Name camera tour is 16.
  • Page 59: System

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Running Enable or disable this camera tour. Set the sequence of the tour. Maximum 16 points can be assigned. The Preset selected preset position is added in the Sequence list from 1 to 16.
  • Page 60: Date & Time

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V the camera is transferring data. Power LED Switch the LED light of this Internet Camera on or off. User can check the system log information of the device, including the Main Info, Appended Info, Operator IP, and so on.
  • Page 61: Maintenance

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Select an interval between 1 and 23 hours at which you want to NTP Sync. Interval adjust the device’s time referring to NTP server Set the time difference from Greenwich Mean Time in the area Time Zone where the device is installed.
  • Page 62 8. A message will be shown while the firmware is upgraded. Once the upgrading process completed, the device will reboot the system automatically. 9. Please wait for 80 seconds, and then you can use PLANET IPWizard II to search the device again. Warning!!! The download firmware procedure cannot be interrupted.
  • Page 63: Video

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.8 Video This device provides 2 modes of video profile. The first one is 2Mega mode which supports video resolution up to 2 mega-pixel. The second one is 2 mega mode which supports video resolution up to 2 mega-pixel.
  • Page 64: Video Profile

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Upload Own Image Select your picture to upload Coordinates Select the location of the picture 3.8.3 Video Profile User can modify the detailed parameter for each video profile on this page.
  • Page 65 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Video Type Video codec of the selected profile. Resolution Resolution of the selected profile. Assign the selected profile as a ROI stream or not (Only available for the profiles with max resolution).
  • Page 66: Roi

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Always Enable Multicast streaming is always enabled or by request Multicast Warning!!! To enable the multicast streaming, make sure your Intranet does support multicast function. Otherwise, your Intranet may fall into network storm seriously.
  • Page 67: Audio

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Add and Del To add or delete the AOI windows, user can specify up to 2 AOI windows to change the video quality in specified areas. By dragging mouse on the image, you can change the position and size of the...
  • Page 68: User Privilege Access

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Audio To enable or disable audio function. Audio type To select G711 or G726 for audio coding. Audio Mode: To select Simplex or Full duplex (2-way audio) mode. Input Gain: To adjust gain of input audio.
  • Page 69: Protocol

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Select “Anonymous” to allow any one viewing the video once Viewer Login connected. Otherwise, only users in database can view the video after login. Administrator can access every function in this device.
  • Page 70: Snmp

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V To enable or disable the ONVIF interface here. ONVIF Currently, the V1.0 or V1.01/1.02/V2.0/V2.1.1 is available. Version 3.11.2 SNMP SNMP provides a simple framework for administering networked hardware. To manage the IP camera, you have to prepare an MIB browser or similar tools first.
  • Page 71: Mail

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V from the manager. Trap Address The IP address of SNMP traps station. Trap Community means the community that can receive the trap Trap Community message. The camera reboots. Available Traps Cold Start...
  • Page 72: Event Detection

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V SMTP Server Type the SMTP server name or the IP address of the SMTP server. Send a test mail to mail server to check this account is available or Test not.
  • Page 73: Camera Tampering

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V To add or delete the motion windows, user can specify up to 4 Included and /or Excluded windows to monitor the video captured by Add and Delete this device. By dragging mouse on the image, you can change the position and size of the selected motion window accordingly.
  • Page 74: Audio Detection

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V images/files to remote server or email. Minimum duration Define the minimum triggered duration by camera tampering detection. The triggered duration less than target value will be ignored to filter false alarms.
  • Page 75: Storage

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Audio Alarm Level Define the threshold value of audio detection. 3.14 Storage This page shows the status of attached SD card and Samba server. You may set up related parameters to manage the attached SD card or Samba server also.
  • Page 76: Samba Server

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Status This information of SD card. Delete old recorded files while the conditions are reached as Enable automatic disk cleanup below. Remove recordings order than Delete old files by days. Remove oldest recordings Delete old files by left capacity.
  • Page 77: Recording List

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.16 Recording List This page shows the files where information is listed inside the SD Card. User may reload file from SD card that plays or removes the selected file. This page shows the files where information is listed inside the SD Card or Samba server. User...
  • Page 78: Event Server

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.17 Event Server 3.17.1 FTP Server You may setup FTP parameters for further operation of Event Schedule. That is, if users want to send the alarm message to an FTP server, it will need to configure parameters here and also add...
  • Page 79: Tcp Server

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Name User can specify multiple FTP paths as wished. Therefore, user needs to specify a name for each FTP setting. FTP Server Type the server name or the IP address of the FTP server.
  • Page 80: Http Server

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.17.3 HTTP Server The device can also send event message to specified HTTP server. Name User can specify multiple HTTP servers as wished. Therefore, user needs to specify a name for each HTTP server setting.
  • Page 81 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Name User can specify multiple HTTP servers as wished. Therefore, user needs to specify a name for each HTTP server setting. SAMBA Server Type the server name or the IP address of the SAMBA server.
  • Page 82: Event Schedule

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V 3.18 Event Schedule This menu is used to specify the schedule of Events and activate the some actions provided by this device. 3.18.1 Setting Name Name of the Event or Schedule.
  • Page 83 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Example1. Send file to FTP server by motion triggered always by:: Select event trigger Enable time: start from 00:00 to 24:00 every day Trigger by: Motion Area (Added in Object Detection page)
  • Page 84 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Example 2. Send file to E-Mail server by motion triggered from Friday 18:00 to Saturday 06:00 Select event trigger. Enable time: start from Friday 18:00 and keep work in 12 hours, so it will stop on Saturday 06:00.
  • Page 85: Record

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Example 3. Enable Voice Alert every 10 minute during 18:00 to 24:00 from Monday to Friday. 1. Type: Select schedule trigger and interval is 10 minutes. 2. Enable Time: Select Monday to Friday, and set start time from 18:00 and keep work in 6 hours.
  • Page 86: Port Status

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Record File Type Choose AVI or JPEG file format for record file. Record File Prefix Define the prefix of recorded filename. Pre-Trigger Duration Define the maximum duration of pre-alarm. Best Effort Duration Define the best effort duration of post-alarm.
  • Page 87: Appendix A: Ping Ip Address

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Appendix A: PING IP Address The PING (stands for Packet Internet Groper) command is used to detect whether a specific IP address is accessible by sending a packet to the specific address and waiting for a reply. It’s also a very useful tool to confirm the installation of Internet Camera, or if the IP address conflicts with any other device over the network.
  • Page 88: Appendix B: 3Gpp Access

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Appendix B: 3GPP Access To use the 3GPP function, in addition to previous section, you might need more information or configuration to make this function works. To use the 3GPP function, it is strongly recommended to install the Networked Device with a public and fixed IP address without any firewall protection.
  • Page 89: Appendix C: Bandwidth And Video Size Estimation

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Appendix C: Bandwidth and Video Size Estimation The frame rate of video transmitted from the Internet Camera depends on connection bandwidth between client and server, video resolution, codec type, and quality setting of server. Here is a guideline to help you roughly estimate the bandwidth requirements for your Internet Camera.
  • Page 90: Appendix D: Ddns Application

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Appendix D: DDNS Application 1. Configure PLANET DDNS steps: Step 1: Enable DDNS option through accessing web page of NAS Step 2. Select on DDNS server provided, and register an account if you have not used yet.
  • Page 91: Appendix E: Configure Port Forwarding Manually

    Manually set up the device with a fixed IP address, for example, 192.168.0.100. 2. Access the Router with Your Web browser The following steps generally apply to any router that you have on your network. The PLANET WNRT-620 is used as an example to clarify the configuration process. Configure the initial settings of the router by following the steps outlined in the router’s Quick Installation Guide.
  • Page 92 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Your WAN IP Address will be listed here. 3. Open/set Virtual Server Ports to enable remote image viewing The firewall security features built into the router and most routers prevent users from accessing the video from the device over the Internet.
  • Page 93 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Enter valid ports in the Virtual Server section of your router. Please make sure to check the box on this line to enable settings. Then the device can be accessed from WAN by the router’s WAN IP Address.
  • Page 94: Appendix F: Power Line Frequency

    5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V Appendix F: Power Line Frequency COUNTRY VOLTAGE FREQUENCY COMMENTS *Neutral and line wires are reversed from that Argentina 220V 50 Hz used in Australia and elsewhere. *Outlets typically controlled by adjacent switch.
  • Page 95: Appendix G: Troubleshooting & Frequently Asked Questions

    5 seconds on the device. 2. Reconfigure the device. Check IP address of device by using the PLANET IP Wizard II Forgot the IP address of the program or by UPnP discovery or set the device to default by Reset device.
  • Page 96 Do not connect device over a router. PLANET IP Wizard II program cannot detect device over a router. If IP address is not assigned to the PC which runs PLANET IP Wizard II program, then PLANET IP Wizard II program cannot PLANET IP Wizard II program find the device.
  • Page 97 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V is forward to the Internet Camera’s private IP address. The port number assigned in your Internet Camera might not be available via Internet. Check your ISP for available port. The proxy server may prevent you from connecting directly to the Internet Camera, set up not to use the proxy server.
  • Page 98 5 Mega-Pixel 20M IR Vari-Focal Dome IP Camera ICA-4500V server running on your LAN. Checking the configuration of the router settings allows the device to be accessed outside your local LAN. Check the bandwidth of Internet connection. If the Internet bandwidth is lower than target bit rate, the video streaming will not work correctly.
  • Page 99 Windows Media Player 11.0 or later to play the AVI filed recorded by the Device. Cannot unmount SD card Because the ICA-4500V series needs about two minutes to stop immediately after stopping recording procedure. Please wait for two minutes later and then run continuous recording unmount SD card.

Table of Contents