PERFORMANCE DATA - OPERATING PRESSURES
PK30+PUG30 (Indoor Air = 990 CFM)
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
29,702
65
30,517
67
31,331
69
32,153
71
32,974
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
27,689
65
28,977
67
30,266
69
31,255
71
32,245
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
25,675
65
27,438
67
29,200
69
30,358
71
31,515
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
23,599
65
25,183
67
26,768
69
28,268
71
29,769
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
21,522
65
22,929
67
24,335
69
26,179
71
28,022
Mitsubishi Electronics 2003
75 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
12.28
2,419
18,029
12.57
2,428
15,612
12.85
2,438
13,196
13.08
2,458
10,787
13.31
2,477
8,378
85 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
10.81
2,561
17,027
11.12
2,606
14,822
11.42
2,650
12,618
11.73
2,665
10,394
12.03
2,680
8,171
95 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
9.50
2,703
16,026
9.85
2,783
14,032
10.20
2,863
12,039
10.57
2,873
10,001
10.93
2,883
7,964
105 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
8.95
2,635
14,612
8.95
2,813
12,912
8.95
2,991
11,212
9.31
3,035
9,213
9.67
3,078
7,213
115 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
8.38
2,568
13,198
8.09
2,844
11,792
7.80
3,120
10,386
8.18
3,197
8,424
8.56
3,274
6,462
Indoor Dry Bulb (°F)
75
80
85
21,421
26,138
30,855
19,004
23,721
28,438
16,588
21,305
26,022
14,179
18,896
23,613
11,770
16,487
21,204
Indoor Dry Bulb (°F)
75
80
85
20,419
25,136
29,853
18,214
22,931
27,648
16,010
20,727
25,444
13,786
18,503
23,220
11,563
16,280
20,997
Indoor Dry Bulb (°F)
75
80
85
19,418
24,135
28,852
17,424
22,141
26,858
15,431
20,148
24,865
13,393
18,110
22,827
11,356
16,073
20,790
Indoor Dry Bulb (°F)
75
80
85
18,004
22,721
27,438
16,304
21,021
25,738
14,604
19,321
24,038
12,605
17,322
22,039
10,605
15,322
20,039
Indoor Dry Bulb (°F)
75
80
85
16,590
21,307
26,024
15,184
19,901
24,618
13,778
18,495
23,212
11,816
16,533
21,250
9,854
14,571
19,288
036-21534-001 Rev. B (0703)
Pressures
(psig)
90
Suction
Discharge
34,247
72
224
31,830
73
225
29,414
74
225
27,005
76
228
24,596
78
230
Pressures
(psig)
90
Suction
Discharge
33,245
75
256
31,040
77
260
28,836
79
264
26,612
81
265
24,389
83
267
Pressures
(psig)
90
Suction
Discharge
32,244
77
287
30,250
81
295
28,257
84
302
26,219
86
303
24,182
88.5
303
Pressures
(psig)
90
Suction
Discharge
30,830
81
326
29,130
83
331
27,430
86
337
25,431
89
339
23,431
92
342
Pressures
(psig)
90
Suction
Discharge
29,416
84
364
28,010
86
368
26,604
88
372
24,642
92
376
22,680
96
380
9