STANDARD OPERATING DATA
PL-AK INDOOR UNITS WITH PUG OUTDOOR UNITS
MODELS
Item
Voltage
Frequency
Total Input
Indoor Fan Current
Booster Heater Current
Outdoor Fan Current (FLA)
Compressor Current (230v)
Condensing Pressure
Suction Pressure
Discharge Temperature
Condensing Temperature
Suction Temperature
Refrigerant Pipe Length
Refrigerant Charge
Intake Air Temperature
Discharge Air Temperature
Fan Speed
Airflow (High)
Intake Air Temperature
Fan Speed
Airflow (High)
Capacity
SHF
Mitsubishi Electronics 2003
PL18AK
Unit
Cooling
V
208/230
Hz
60
kW
1.82
A
0.8
A
--
A
0.5
A
7.3
PSIG
223
PSIG
84
°F
165
°F
91
°F
60
FT
25
--
3 lbs 14 oz
DB
°F
80
WB
°F
67
DB
°F
59
WB
°F
58
RPM.
1490
CFM
710
DB
°F
95
WB
°F
--
RPM.
1050
CFM
1785
BTU/H
20000
--
0.75
036-21534-001 Rev. B (0703)
PL24AK
PL30AK
PL36AK
Cooling
Cooling
Cooling
208/230
208/230
208/230
60
60
2.38
2.85
0.8
0.9
--
--
0.5
0.5
9.6
12.6
270
283
85
80
191
197
112
108
58
59
25
25
4 lbs 3 oz
4 lbs 2 oz
4 lbs 10 oz
80
80
67
67
58
59
57
57
1490
1490
990
1060
95
95
--
--
1050
1050
1785
1835
24000
28400
0.81
0.75
PL42AK
Cooling
208/230
60
60
3.34
4.35
1.0
1.4
--
--
1.4
1.4
14.0
16.4
280
267
82
71
190
192
111
104
62
50
25
25
5 lbs 3 oz
80
80
67
67
59
59
57
57
1490
1490
1060
710
95
95
--
--
1100
1100
2340
3320
35600
41000
0.69
0.67
5