Mitsubishi PUG18AYB Technical Manual page 11

Mitsubishi pug18ayb; pug24ayb; pug30ayb; pug36ayb; pug42ayb split-type, air conditioners, pug outdoor unit
Table of Contents

Advertisement

4
PERFORMANCE DATA - OPERATING PRESSURES
PL18+PUG18 (Indoor Air = 600 CFM)
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
19,879
65
20,894
67
21,477
69
22,451
71
22,913
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
18,970
65
19,823
67
20,739
69
21,600
71
22,173
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
18,060
65
18,751
67
20,000
69
20,749
71
21,432
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
16,787
65
17,098
67
18,264
69
19,169
71
20,018
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
15,514
65
15,445
67
16,528
69
17,588
71
18,603
Mitsubishi Electronics 2003
75 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
12.21
1,629
11,583
12.72
1,643
10,125
12.95
1,658
8,668
13.50
1,663
6,954
13.73
1,668
5,240
85 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
10.86
1,746
11,093
11.24
1,764
9,760
11.64
1,781
8,428
12.06
1,790
6,639
12.32
1,799
4,850
95 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
9.69
1,863
10,603
9.95
1,884
9,395
10.50
1,905
8,188
10.82
1,918
6,324
11.10
1,931
4,460
105 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
8.43
1,992
9,300
8.52
2,007
8,455
9.03
2,022
7,610
9.38
2,044
5,754
9.69
2,066
3,898
115 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
7.32
2,121
7,997
7.25
2,130
7,515
7.73
2,138
7,033
8.11
2,170
5,184
8.45
2,202
3,335
Indoor Dry Bulb (°F)
75
80
85
14,989
18,395
21,801
13,532
16,938
20,344
12,074
15,480
18,886
10,360
13,766
17,172
8,646
12,052
15,458
Indoor Dry Bulb (°F)
75
80
85
14,499
17,905
21,311
13,166
16,573
19,979
11,834
15,240
18,646
10,045
13,451
16,857
8,256
11,662
15,068
Indoor Dry Bulb (°F)
75
80
85
14,009
17,415
20,821
12,801
16,207
19,613
11,594
15,000
18,406
9,730
13,136
16,542
7,867
11,273
14,679
Indoor Dry Bulb (°F)
75
80
85
12,706
16,112
19,518
11,861
15,267
18,673
11,016
14,422
17,828
9,160
12,566
15,972
7,304
10,710
14,116
Indoor Dry Bulb (°F)
75
80
85
11,403
14,809
18,215
10,921
14,327
17,733
10,439
13,845
17,251
8,590
11,996
15,402
6,741
10,147
13,553
036-21534-001 Rev. B (0703)
Pressures
(psig)
90
Suction
Disch.
25,207
71
200
23,750
73
204
22,293
75
208
20,578
81
210
18,864
86
212
Pressures
(psig)
90
Suction
Discharge
24,717
75
233
23,385
77
236
22,052
80
240
20,263
84
241
18,474
88
243
Pressures
(psig)
90
Suction
Discharge
24,227
79
265
23,020
82
268
21,812
84
271
19,948
87
273
18,085
89
274
Pressures
(psig)
90
Suction
Discharge
22,924
84
303
22,079
86
305
21,235
88
308
19,378
90
310
17,522
93
313
Pressures
(psig)
90
Suction
Discharge
21,621
89
341
21,139
90
343
20,657
91
344
18,808
94
348
16,959
97
352
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pug24aybPug30aybPug36aybPug42ayb

Table of Contents