PERFORMANCE DATA - OPERATING PRESSURES
PC30+PUG30 (Indoor Air = 830 CFM)
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
30,312
65
31,133
67
31,975
69
33,452
71
33,652
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
28,257
65
29,536
67
30,887
69
32,184
71
32,907
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
26,203
65
27,939
67
29,800
69
30,916
71
32,163
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
24,083
65
25,476
67
27,318
69
28,562
71
30,380
Cooling
Indoor Wet
Capacity
Bulb (°F)
(Btu/hr)
63
21,964
65
23,013
67
24,835
69
26,207
71
28,598
Mitsubishi Electronics 2003
75 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
11.62
2,609
20,799
11.65
2,620
15,807
12.16
2,630
15,224
12.36
2,651
11,010
12.59
2,672
9,665
85 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
10.23
2,762
19,644
10.51
2,811
17,100
10.80
2,859
14,556
11.19
2,875
11,991
11.38
2,891
9,426
95 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
8.99
2,915
18,488
9.31
3,002
14,457
9.65
3,088
13,889
9.98
3,099
10,108
10.34
3,110
9,187
105 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
8.47
2,843
16,857
8.39
3,035
13,074
8.47
3,227
12,935
8.72
3,274
9,203
9.15
3,321
8,321
115 °F Outdoor Air Temperature
Net Sensible Cooling Capacity (Btu/hr)
Total
EER
Power
(Watts)
70
7.93
2,770
15,226
6.85
3,068
11,692
7.38
3,365
11,981
7.60
3,448
8,298
8.10
3,531
7,455
Indoor Dry Bulb (°F)
75
80
85
24,712
30,154
35,596
20,127
24,447
28,766
19,137
24,579
30,021
15,329
19,649
23,969
13,579
19,020
24,462
Indoor Dry Bulb (°F)
75
80
85
23,557
28,999
34,440
21,013
26,455
31,897
18,470
23,911
29,353
15,905
21,346
26,788
13,340
18,781
24,223
Indoor Dry Bulb (°F)
75
80
85
22,401
27,843
33,285
18,776
22,947
27,416
17,802
23,244
28,686
14,428
18,598
23,067
13,101
18,542
23,984
Indoor Dry Bulb (°F)
75
80
85
20,770
26,212
31,654
17,394
21,639
26,033
16,848
22,290
27,732
13,523
17,768
22,162
12,235
17,676
23,118
Indoor Dry Bulb (°F)
75
80
85
19,139
24,581
30,023
16,012
20,331
24,651
15,895
21,337
26,778
12,618
16,938
21,257
11,369
16,811
22,252
036-21534-001 Rev. B (0703)
Pressures
(psig)
90
Suction
Discharge
39,509
71
228
33,086
72
229
33,934
73
229
28,288
75
232
28,375
77
234
Pressures
(psig)
90
Suction
Discharge
38,354
74
260
35,810
76
264
33,266
78
268
30,701
80
269
28,136
82
271
Pressures
(psig)
90
Suction
Discharge
37,198
76
291
31,736
80
299
32,599
83
306
27,387
85
307
27,897
88
307
Pressures
(psig)
90
Suction
Discharge
35,567
80
330
30,353
82
335
31,645
85
341
26,482
88
343
27,032
91
346
Pressures
(psig)
90
Suction
Discharge
33,936
83
368
28,971
85
372
30,692
87
376
25,577
91
380
26,166
95
384
17