Water Separator - TOHATSU BFT 250A Owner's Manual

Hide thumbs Also See for BFT 250A:
Table of Contents

Advertisement

MAINTENANCE

Water Separator

No.6 CYLINDER IGNITION COIL
WATER SEPARATOR
Water separator is located under No.6
cylinder ignition coil. Water
accumulation in the water separator
can cause loss of power or hard
starting. Check the water separator
periodically. Clean it or consult with
an authorized TOHATSU outboard
motor dealer for cleaning.
94
Gasoline is extremely 
flammable, and gasoline vapor can
explode, causing serious injury or
death. Do not smoke or allow
flames or sparks in your working
area.
KEEP OUT OF REACH OF
CHILDREN.
• Always work in a well-ventilated
area.
• Be sure that any fuel drained
from the outboard motor is
stored in a safe container.
• Be careful not to spill fuel when
replacing the filter. Spilled fuel or
fuel vapor may ignite. If any fuel
is spilled, make sure the area is
dry before starting the engine.
<Cleaning>
6 × 17 mm SPECIAL BOLTS
LEFT
UNDER
COVER
6 × 17 mm
SPECIAL BOLTS
1. Remove the engine cover (see page
39).
2. Remove the spark plug
maintenance cover (see page 87).
3. Remove the cover under the idle
port.
4. Remove the left under cover by
removing the 6 × 17 mm special
bolts.
IDLE
PORT
COVER

Advertisement

Table of Contents
loading

Table of Contents