Rinnai ENERGYSAVER EX08C Installation Fundamentals page 28

Direct vent wall furnace
Hide thumbs Also See for ENERGYSAVER EX08C:
Table of Contents

Advertisement

Installation Guidelines
The following guidelines are from the installation / owner's manual.
Before beginning the installation process, please review the following:
• This appliance discharges a large volume of warm air next to the floor. Any particles
in the air such as cigarette smoke could cause discoloration in carpet. The warm air
flow could discolor nylon carpets containing dyes or vinyl surfaces. To prevent
discoloration of the floor covering a mat may be placed under the appliance which
extends about 30 inches (750 mm) in front of it.
• This appliance is not designed to be built in.
• This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases unless a certified kit is used. If
a conversion of the unit is needed, conversions must be performed by a qualified
service provider at the owner's expense.
• This appliance must not be connected to a chimney flue serving a separate solid-
fuel burning appliance.
• A shut off valve (and appliance connector valve) should be installed in the upstream
of the gas line to permit servicing. This valve is included.
28