Parameter Function
Event
The abnormal events include: No disk, disk error, disk no space, net
Type
disconnection, IP conflict and MAC conflict.
You can set one or more items here.
Less than: You can set the minimum percentage value here (For disk
not space only). The device can alarm when capacity is not sufficient.
You need to draw a circle to enable this function.
Enable
Check the box here to enable selected function.
Alarm Out
Please select corresponding alarm output channel when an alarm
occurs. You need to check the box to enable this function.
Latch
The alarm output can delay for the specified time after an alarm stops.
The value ranges from 1s to 300s.
Show
System can pop up a message to alarm you in the local host screen if
message
you enabled this function.
Alarm
System can upload the alarm signal to the centre (Including alarm
upload
centre.
Send
If you enabled this function, System can send out an email to alert you
Email
when an alarm occurs.
Buzzer
Check the box here to enable this function. The buzzer beeps when an
alarm occurs.

5.8.4 Storage

5.8.4.1 Schedule
In this interfaces, you can add or remove the schedule record/snapshot setup. See Figure 5-55.
There are three record modes: general (auto), motion detect and alarm. There are six periods in one day.
You can view the current time period setup from the color bar.
Green color stands for the general record/snapshot.
Yellow color stands for the motion detect record/snapshot..
Red color stands for the alarm record/snapshot.
Blue color stands for MD&alarm record/snapshot.
Figure 5-55