Procedure
(Cont.)
Increasing the
Lamp's Life
Rogue™ RH1 Hybrid User Manual Rev. 1
4. Take note as to the orientation of the lamp. Vent holes on the front of the lamp should align
horizontally with the air vents on the lamp frame. This is extremely important for lamp cooling
when replacing the lamp. (see step 5 for location of vents on the lamp) Using the lamp base,
push the lamp down against the spring clips and then roll the lamp out the top.
Lamp Cooling
Vents
5. Remove the 2 wires connected to the lamp by the spade connectors.
Lamp Vents
6. Reverse the steps 5 through 1 above to install the new lamp. Do not touch the glass with
bare hands.
RISK OF LAMP EXPLOSION! Vent holes on the front of the lamp should align horizontally
with the air vents on the lamp frame. This is extremely important for lamp cooling
Do not turn product on without a lamp!
Vent holes on the front of the lamp should align horizontally with the air vents on the
·
lamp frame. This is extremely important for lamp cooling.
·
ALWAYS turn the lamp off by using the DMX controller or the product's control panel,
then wait at least 5 minutes before switching off the product. This will keep the fans
running to extract any remaining heat from the product's head.
·
DO NOT power cycle the product unless it is necessary.
·
DO NOT re-strike the lamp immediately after turning it off. Chauvet recommends
waiting 5 minutes before trying to re-strike the lamp.
·
DO NOT touch the lamp without wearing gloves to avoid leaving grease on the bulb or
on the contacts that could reduce the lamp's life.
ALWAYS change the lamp when it has reached its recommended lifespan to avoid the
·
risk of lamp explosion.
Spade Connectors
Setup