6
Electrical installation
Connecting the supply and peripheral devices
Terminal diagram supply
6.3
Connecting the supply and peripheral devices
6.3.1
Terminal diagram supply
L1
N
PE
)
Note!
ƒ
ƒ
6.3.2
24 V connection (X101)
0V
U
38
0
USV
0 V
PE +24 V
+
2
3
0
IPC
1
Power supply unit
2
Battery pack (Option)
3
Capacitor pack (Option)
Observe the max. permissible input voltage.
Professionally fuse the device on the input side against voltage fluctuations
and voltage peaks.
The IPC boots up as soon as the supply voltage is applied.
After the operating system has been shut down, the IPC switches off
automatically. For restarting, the supply voltage has to be disconnected for a
short time.
Description
DC 24 V connection
IPC001
PE connection
IPC001
l
S
F
+
L1 N
~
=
1
+
0V
+24
Connection type
3−pole Phoenix Combicon
cross−section max. 2.5 mm
socket
with Phoenix Combicon plug,
Separate earthing conductor
M4 threaded bolt
Elx7xx−006
Cable type
Cable (conductor
2
)
MSTB 2.5 / 3−STF−5.08
2
(min. 2.5 mm
) with ring
cable lug
BA_ELx8xx EN 3.0