4
Technical data
General data and operating conditions
4
Technical data
4.1
General data and operating conditions
General data
Conformity and approval
Conformity
CE
Approbation
UL
Other
RoHS
Protection of persons and equipment
Safety
Enclosure
Class of protection
EMC
Noise emission
Noise immunity Zone B
*
Due to the high−energy single current pulses, a surge requires a suitable external connection with lightning
protection elements like for instance lightning conductors and overvoltage arresters.
26
EN 61000−6−4
EMC Directive Class A, industrial premises
EN 61000−6−2
UL 508
Programmable Controllers (File−No. E236341)
CSA C22.2
−
Products lead−free in accordance with CE Directive
2011/65/EU
VDE0805 (EN60950),
VDE0870, UL
EN 60529
IP65 (front) / IP20 (back)
UL 508 (NEMA 250)
Type 1 enclosure
3
EN 61000−6−4
Class A (industrial premises)
EN 61000−6−2
Industrial premises
EN 61000−4−2
EN 61000−4−3
EN 61000−4−4
EN 61000−4−5
EN 61000−4−6
l
ESD; severity: 3, i.e.
8 kV in the case of air discharge,
4 kV in the case of contact discharge
RF interference (housing)
80 MHz
1000 MHz, 10 V/m 80 % AM (1 kHz)
Burst, severity: 3
Surge, severity 3 *
RF conducted
150 kHz
80 MHz, 10 V/m 80 % AM (1 kHz)
BA_ELx8xx EN 3.0