Safety Instructions For The Installation According To Ul - Lenze EL 1800 Operating Instructions Manual

L?force controls
Hide thumbs Also See for EL 1800:
Table of Contents

Advertisement

2.3

Safety instructions for the installation according to UL

Original − English
Approval
Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File Number
E236341)
Ratings
Input 24 V DC, 65 W
ƒ
Max. Ambient Temperature 40 °C
ƒ
– EL6xx, EL1xxx, EL5xxx, EL9xxx only
Max. Surrounding Temperature 50 °C
ƒ
– EL8xx, EL2xxx, EL7xxx only
Optional communication ratings:
ƒ
– RS232−Connection: max. 3 A
– USB−Connection: max. 1 A
– PS/2−Connection: max. 1 A
– LAN−Connection: Standard ISDN or RJ45
Environmental ratings: If these devices are mounted into a door or front cover of an
ƒ
enclosure: Type 1 enclosure.
J
Warnings!
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒ
ƒ
ƒ
Power supply
ƒ
ƒ
Battery
ƒ
ƒ
ƒ
BA_ELx8xx EN 3.0
Safety instructions for the installation according to UL
Use Copper Wire only.
AWG 18 ... AWG 12 (0.82 mm
Torque 5...7 lb−in (0.5 ... 0.6 Nm)
Must be used as isolating source.
Rated data: 24 VDC, 4 A max.
Replace Battery with any from the list below, Part No. CR 2450 only. Use of
another battery may present a risk of fire or explosion.
Recommended CR2450 (R/C, BBVC2) types:
Renata Part.no. CR2450N, Sony Corp. part no. CR2450B, Toshiba part no.
CR2450, Varta part no. CR2450, Matsushita part no. CR2450
Battery may explode if mistreated. Do not recharge, disassemble, dispose of
in fire or heat above 100 °C (212 °F).
Dispose of used battery according to the regulation of recycling or waste.
l
Safety instructions
2
2
... 3.3 mm
)
2
13