Radiant Tube Assembly - Brant Radiant Heaters DX2-20-60 User Manual

Gas-fired infrared tube heater
Table of Contents

Advertisement

3.0
Installation

Radiant Tube Assembly

Radiant Tube Assembly
To install the radiant tubes:
Place tubes in hangers with the welded seam facing downward and the swaged end of the tube
1
towards the exhaust end of the heater system (see figure 3.8).
Refer to the Series Insert Manual for tube installation sequence.
Figure 3.8
Attach Hangers
Hanger
Slide tube clamps onto radiant tubes (see figure 3.9).
2
Figure 3.9
Attach Tube Clamps
Concave surface
Radiant Tube
Welded seam
faces down
NOTE: If the tube clamp comes
apart, the spacer must be
re-assembled with the spacer's
concave surface facing against
the radiant tube surface.
IMPORTANT! 175,000 to 200,000 BTU/h models must be
installed with a stainless steel tube clamp (P/N: TP-220) located at
the seam between the primary combustion chamber and the
second tube section downstream of the burner control box.
18
DX2
Series
Swaged End
Tube Clamp

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents