Burner Control Box Suspension - Brant Radiant Heaters DX2-20-60 User Manual

Gas-fired infrared tube heater
Table of Contents

Advertisement

DX2
Series

Burner Control Box Suspension

Suspending the burner control box must be done in accordance with applicable codes listed in the Safety
section and these instructions.
The burner control box must be in straight alignment with all radiant tubes and level. Contact your local
distributor or the factory to see if your application allows for the rotation of the burner control box.
Determine the mounting chain locations for hanging the burner control box.
1
Fasten beam clamp, screw hook or other type of suspension anchor to hanging point.
2
Attach S-hook and #1 double loop chain (P/N: THCS) to anchor. Check that it is securely connected.
3
Attach chain assemblies and S-hooks to mounting brackets on the burner control box. Adjust chain lengths
4
until level and in straight alignment with all radiant tubes. Burner sight glass will be visible from the floor.
Figure 3.14
Burner Control Box Assembly
1
8.1"
Figure 3.15
Burner Control Box showing U-Shaped Configuration
3.5"
Side View
2
3
Burner tube is in straight
alignment with 10 ft. Primary
Combustion Chamber
4
Burner Sight Glass
(bottom side of the tube)
12"
29.6"
16"
T
120V
NEUTRAL
EART
- 120V HEATER INPUT -
5.5"
21
3.0
Installation
Burner Control Box Suspension
16"
End View
5"
18"
8.1"
3"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents