Locating Stove - Vogelzang International BX22EL Owner's Manual

Boxwood stove
Hide thumbs Also See for BX22EL:
Table of Contents

Advertisement

ASSEmblY INSTRUCTIONS continued...
10. Place the slide draft into position on the hearth,
illustration F. Hold in position with round head stove
bolt (C) and large flat washer (D).
11. Lower feed door into position while aligning hinge
pins.

lOCATINg STOvE

Proper clearances must be maintained for ad-
equate air circulation. Adequate ventilation must be
provided while operating this stove.
1. The stove must be placed on solid concrete, solid
masonry, or when installed on a combustible floor,
on a listed floor protector, such as Hy-C or Impe-
rial Model UL 3648BK, a 1/2" thick floor protector
with a R-factor of 0.84 or equivalent (see page
14 to calculate R-factors of alternative materials).
The base must extend at least 16" beyond the
front of the hearth, 8" to the sides of the stove,
and must extend under the stove pipe and 2˝
on either side if it is elbowed towards a wall (see
figure 1 and consult local building codes and fire
protection ordinances.)
CAUTION: (FIRE HAzARD) CARPETING AND
OTHER COmBUSTIBLE mATERIAL mUST NOT
COVER THE FLOOR PROTECTOR. THESE
mATERIALS mUST REmAIN OUTSIDE OF
COmBUSTIBLE CLEARANCES, SEE FIG. 1- 2.
2. The stove must have its own flue. DO NOT
CONNECT THIS UNIT TO A CHImNEY FLUE
SERVING OTHER APPLIANCES.
3. After observing the clearances to combus-
tible materials (figure 1 & 2), locate your floor
protector accordingly (figure 1) and careful-
ly place the stove in your selected location.
Install connector pipe, elbows, and thimble as
required, utilizing either a recently cleaned and
inspected 6" masonry chimney or a 6" i.d. listed
chimney, maximum 64 square inches.
Page 4
/ BX22EL
ill. E – Damper Collar
ill. F – Slide Draft,
Door & S-Hook Location
(lid lifter storage)
12. Place S-Hook in hole at left front corner of hearth.
Note: S-Hook is used to hang lid lifter while not
in use.
4. Use round, 6" dia., minimum 24 MSG (minimum
standard gauge) black or 26 MSG blue steel stove
pipe. DO NOT use galvanized stove pipe. Secure
pipe sections with three (3) sheet metal screws in
each stove pipe and/or elbow joint to firmly hold the
pipe sections together. DO NOT CONNECT THIS
STOVE TO ANY AIR DISTRIBUTION OR DUCT
SYSTEm.
5. R e c h e c k c l e a r a n c e s f r o m t h e s t o v e ,
connector stove pipe, and corner clearances
using the location drawings (figure 1 & 2) and
your local building codes or fire protection
ordinances.
NOTE: Drywall faced with brick or stone must be
considered a combustible surface.
6. Do Not iNstall this stove iN a mobile home,
maNufactureD home, trailer or teNt – NO
EXCEPTIONS! (HUD Federal Standard: 24 CFR
Ch.XX)
7. T h e c l e a r a n c e s p r o v i d e d a r e m i n i m u m
dimensions determined by NFPA. Installation of
this stove must comply with the latest edition of
NFPA 211 for reduced clearances and/or your lo-
cal building code rulings. Use whichever minimum
dimensions are LARGEST.
Failure to follow these minimum clear-
ance requirements may result in an unsafe
installation and could cause a fire.