SENTRY COAL
Model VG810CL
Le manuel de langue français est disponible à www.vogelzang.com
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS
ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
VGZ-011 / 20120105.0
(Save These Instructions)
French language manual is available at www.vogelzang.com
STOVE

Owners Manual

This stove meets test standards:
US: UL 1482-2011 & CDN: ULC-S627-00
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
EQUIPMENT INSTALLER!
DO NOT INSTALL IN A MOBILE HOME.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
VG810CL SENTRY COAL™ /
Report No. J99014323-231
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Vogelzang International Sentry Coal VG810CL

  • Page 1: Owners Manual

    SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...
  • Page 2: Safety Precautions

    SAFETY INSTRUCTIONS Read All Instructions carefully. not safe. Use approved masonry or an Underwriters Laboratories Listed UL 103 HT (USA) / ULC-S629 1. The installation of this stove must comply with your (CDN) Listed Residential Type and Building Heating local building code rulings. Please observe the clear- Appliance Chimney.
  • Page 3 SAFETY INSTRUCTIONS continued… needed to clear smoke and/or odor. Paint discoloration STALLED IN A HALLWAY OR NEAR A STAIRCASE, will occur if the stove is over fired. as it may block egress in the event of a fire. 18. T h i s s t ove h a s a p a i n t e d s u r fa c e w h i c h 32.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS SAFETY PRECAUTIONS ................2 – 3 TOOLS AND MATERIALS REQUIRED FOR INSTALLATION ......5 ASSEMBLY INSTRUCTIONS ................5 LOCATING THE STOVE ..................6 Floor Protector, Minimum Clearances ..........6–7 Draft Pipe Damper ................. 7–8 CONNECTOR PIPE INSTALLATION ..............8 CHIMNEY CONNECTIONS ................
  • Page 5: Tools And Materials Required For Installation

    ASSEMBLY INSTRUCTIONS TOOLS AND MATERIALS REQUIRED FOR INSTALLATION tools materials (NOTE: The following items are NOT included with your stove) Pencil 6 ft / 2m Folding Rule or Tape Measure Connector Pipe: 6˝/152mm black steel (24 ga. min.) straight stove Tin Snips pipe or elbow (as required) Drill: Hand or Electric...
  • Page 6: Locating The Stove

    LOCATING STOVE 1. The stove must be placed on solid concrete, solid and/or elbow joint to firmly hold the pipe sections masonry, or when installed on a combustible floor, together. DO NOT CONNECT THIS STOVE TO a solid-surface, non-combustible floor protec- ANY AIR DISTRIBUTION OR DUCT SYSTEM.
  • Page 7: Draft Pipe Damper

    LOCATING STOVE continued… CAUTION: KEEP FURNISHINGS AND OTHER NOTE: BEFORE FIRING STOVE SLIDE FIRE- COMBUSTIBLE MATERIALS AWAY FROM THE BRICKS TOWARDS THE REAR SO NO GAPS STOVE. REMAIN BETWEEN BRICKS. 23"/ 18"/ 58.4cm 18"/ 45.7cm 45.7cm 14"/ 35.6cm 28"/71.2cm 16"/ 40.6cm FLOOR PROTECTOR FLOOR PROTECTOR...
  • Page 8: Connector Pipe Installation

    DRAFT DAMPER continued . . . 2. Remove the handle from the damper then slide the NOTE: This damper is necessary for the prop- damper into the pipe. er operation of the stove and to meet EPA emissions requirements for heating appli- 3.
  • Page 9: Chimney Connections

    CHIMNEY CONNECTIONS The stove must be connected to either a lined ma- CHIMNEY THIMBLE sonry or manufactured metal chimney built and tested FLUE COLLAR to the specifications listed on the previous pages. 6˝/152mm ROUND Chimneys perform two functions: 24 ga. BLACK 5/8"/16mm STOVEPIPE TILE...
  • Page 10 CHIMNEY CONNECTIONS continued … Manufactured Chimney REFER TO CHIMNEY AND CHIMNEY CONNEC- TOR MAKER’S INSTRUCTIONS FOR INSTALLATION AND USE. Use only 6˝/152mm diameter chimney with UL 103 HT (USA) or ULC-S629 (CDN) listing. Chimney made to this listing is High Temperature rated to 2100°F/1149°C. Use chimney from only one manufacturer.
  • Page 11: Fireplace Installation

    CHIMNEY CONNECTIONS continued … installation. This is a complicated and involved process CAUTION: NOT ALL FIREPLACE CHIMNEYS and to ensure safety should only be done by a quali- ARE SUITABLE FOR CONVERSION TO AC- fied installer. COMMODATE A WOOD STOVE. CHECK WITH 1.
  • Page 12: Chimney Connection Systems & Clearances (Nfpa 211)

    CHIMNEY CONNECTOR SYSTEMS & CLEARANCES NOTE: IN CANADA, THE INSTALLATION MUST CONFORM TO CAN/CSA-B365 WHEN PASSING THROUGH COMBUSTIBLE CONSTRUCTION. A. Brick Masonry Minimum 3.5˝/ 89mm thick brick masonry all framed into combustible wall with a minimum of 12˝/305mm brick separation from clay liner to combustibles. The fireclay liner shall run from outer surface of brick wall to, but not beyond, the inner surface of chimney flue liner and shall be firmly cemented in place.
  • Page 13: Operating Instructions

    OPERATING INSTRUCTIONS This stove is designed to burn CAUTION: HOUSE FIRE HAZARDS COAL FUEL ONLY. • GASSES EMITTED FROM FRESHLY ADDED COAL MUST BE BURNED OR THEY WILL AC- THE USE OF WOOD IN THIS STOVE EXCEPT CUMULATE AND EXPLODE. NEVER SMOTHER FOR INITIAL COAL IGNITION PURPOSES IS A A FIRE WHEN ADDING FRESH COAL.
  • Page 14: Thermostat

    OPERATING INSTRUCTIONS continued … 2. Add fuel being careful not to overload or over fie 8. Empty ash pan regularly. Do not allow ashes to pile the stove. Never smother the fire when adding coal. up higher than the sides of the ash pan. If ashes Incomplete combustion of fresh coal will cause gas build up to the grate, it can warp and burnout will accumulation and a mild smokey explosion will oc-...
  • Page 15: Service Hints

    SERVICE HINTS Recommendations for burning Anthracite CREOSOTE – Formation and Need for Coal Removal 1. When burning coal, it is important to maintain a CAUTION: RISK OF FIRE When coal is burned clean chimney. Inspect chimney connector and slowly, it produces tar and other organic vapors, chimney at least twice monthly during the heating which combine with expelled moisture to form season.
  • Page 16: Chimney Draft

    SERVICE HINTS 4. Burn with the air control open for several minutes Correct any draft related issues before using the stove. Please note that one or more factors may play at numerous intervals throughout the day, being a role in a draft issue and certain factors may change careful not to over fire the unit.
  • Page 17: Parts - Sentry Coal™ Stove

    – VG810CL S RDERING ENTRY OAL™ TOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided on the following pages to identify parts. Part No.
  • Page 18 – VG810CL S RDERING ENTRY OAL™ TOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustrations and part lists provided on the following pages to identify parts. Part No.
  • Page 19: Optional F-1 Blower Wiring Diagram

    WIRING DIAGRAM F-1 BLOWER OPTION DANGER: SHOCK HAZARD. DISCONNECT POWER SOURCE BEFORE INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY. CAUTION: MOVING PARTS CAN CAUSE INJURY. DO NOT OPERATE WITH COVER REMOVED. NOTICE: ANY REPLACEMENT WIRING MUST HAVE EQUIVALENT INSULATION AND TEMPERATURE RATING (105°C). Page 19 VGZ-011 / 20120105.0 VG810CL SENTRY COAL™...
  • Page 20: Floor Protector Calculations

    FLOOR PROTECTOR MATERIAL CALCULATIONS This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in the installation instructions on page 6, “Locating Stove” step 1, of this manual. If the floor protector materials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
  • Page 21 Page 21 VGZ-011 / 20120105.0 VG810CL SENTRY COAL™ /...
  • Page 22 “FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT WHOEVER BELIEVES IN HIM SHALL NOT PERISH BUT HAVE ETERNAL LIFE” JOHN 3:16 MADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...