Vogelzang International BK150E Owner's Manual

Vogelzang International BK150E Owner's Manual

Deluxe barrel stove kit

Advertisement

Deluxe BARRel stove KIt
model BK150E
NOTE: A PROFESSIONAL, LICENSED HEAT-
ING AND COOLING CONTRACTOR SHOULD
BE CONSULTED IF YOU HAVE qUESTIONS
REGARDING THE INSTALLATION OF THIS
SOLID FUEL BURNING APPLIANCE.
READ ALL INSTRUCTIONS CAREFULLY BE-
FORE STARTING THE INSTALLATION OR OP-
ERATING THE STOVE. FAILURE TO FOLLOw
INSTRUCTIONS mAY RESULT IN PROPERTY
DAmAGE, BODILY INjURY, OR EVEN DEATH.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE mAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERmITS,
RESTRICTIONS, AND INSTALLATION REqUIREmENTS FOR YOUR AREA.
VGZ-024 / 20120410.2
(save this manual for future reference)
www.vogelzang.com
Owners manual
For use with 30 – 55 gallon closed
head-style steel barrels only.
Double Barrel Stove Kit BK50E
(does not include barrels)
For use with 30 – 55 gallon closed
head-style steel barrels only.
Not
DO
INSTALL THIS STOVE IN A mOBILE
HOmE, mANUFACTURED HOmE, TENT, OR
TRAILER – NO EXCEPTIONS!
NOTE: THIS STOVE IS
Not
A UL LISTED STOVE.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
(kit does not
include barrel)
Page 1
BK150E /

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BK150E and is the answer not in the manual?

Questions and answers

Summary of Contents for Vogelzang International BK150E

  • Page 1 Deluxe BARRel stove KIt Owners manual model BK150E (save this manual for future reference) (kit does not include barrel) For use with 30 – 55 gallon closed head-style steel barrels only. Double Barrel Stove Kit BK50E (does not include barrels)
  • Page 2: Safety Instructions

    Never vent to another room or in- the first 12 to 15 fires. Additional smoke and odor may side a building. DO NOT CONNECT THIS UNIT Page 2 / BK150E Vogelzang International Corp. VGZ-024 / 20120410.2...
  • Page 3 EXPLOSIVE OR FLAmmABLE GASSES. mAKE 32. Install at least one smoke detector on each floor of your SURE BARRELS ARE THOROUGHLY CLEANED home. Detectors should be located close to sleeping ar- BEFORE INSTALLING STOVE KIT. Page 3 VGZ-024 / 20120410.2 www.vogelzang.com BK150E /...
  • Page 4: Assembly Instructions

    ASSEmblY INSTRUCTIONS NOTICE: Vogelzang International Corp . grants no warranty, stated or implied for the assembly, installation or maintenance of your barrel stove kit and assumes no responsibility of any incidental or consequential damages . tools required materials required (NOTE: The following items are NOT included with your stove)
  • Page 5: Locating Stove

    NOTE: DRYwALL FACED wITH BRICK OR STONE Must BE CONSIDERED A COmBUSTIBLE SURFACE. Fig. 3 – Floor Protector Clearances Fig. 5 – Minimum Clearances Page 5 VGZ-024 / 20120410.2 www.vogelzang.com BK150E /...
  • Page 6: Connector Pipe Installation

    3. You must have at least 18˝/457mm of clearance NECTOR PIPE AS A CHImNEY! A HOUSE FIRE between any horizontal piping and the ceiling. COULD RESULT. CORRECT wRONG wRONG Fig. 6 – Stovepipe/Flue Connections Page 6 / BK150E Vogelzang International Corp. VGZ-024 / 20120410.2...
  • Page 7: Chimney Connections

    4. Never use a chimney to ventilate a cellar or basement. 5. Contact your local building authority for approved methods of installation and any necessary permits and/or inspections. Fig. 8 - Chimney Construction Through Attic Space Page 7 VGZ-024 / 20120410.2 www.vogelzang.com BK150E /...
  • Page 8 Fig. 10 - Chimney Connection to Firebox walls. Although many prefabricated fireplaces carry Through Noncombustible (Masonry) Wall continued on next page Page 8 / BK150E Vogelzang International Corp. VGZ-024 / 20120410.2...
  • Page 9: Fireplace Installation

    Make sure the thimble is flush with the inner surface of the chimney liner and does not protrude into the flue (see figure 8 on page 6). Fig. 11 - Fireplace Conversion Page 9 VGZ-024 / 20120410.2 www.vogelzang.com BK150E /...
  • Page 10 24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. Page 10 / BK150E Vogelzang International Corp. VGZ-024 / 20120410.2...
  • Page 11: Operating Instructions

    6” cast iron stove pipe damper in the VICINITY OF THE STOVE — wHETHER IN USE damper/collar. OR IN STORAGE. 9. DO NOT TOUCH the barrel stove after firing until it has cooled. continued on next page Page 11 VGZ-024 / 20120410.2 www.vogelzang.com BK150E /...
  • Page 12: Adding Fuel

    1. Creosote will inevitably form in your chimney and REPLACE ImmEDIATELY IF STOVEPIPE IS connector pipe. Following these steps will help RUSTING OR LEAKING SmOKE INTO THE reduce the rate of build up. ROOm. Page 12 / BK150E Vogelzang International Corp. VGZ-024 / 20120410.2...
  • Page 13 2. If the chimney temperature is too cool, water will condense in the chimney and run back into the stove. Creosote formation will be rapid and may block the chimney. Operate the stove at a fire level high Page 13 VGZ-024 / 20120410.2 www.vogelzang.com BK150E /...
  • Page 14 ORDERINg PARTS - bK150E bARREl STOVE KIT When ordering missing or replacement parts, always give the model Number of the stove, Part Number, and Part Description. Use the illustration and parts list provided to identify parts. Contact us at 616-396-1911 to order parts.
  • Page 15 Use this chart to record inspection & maintenance service to help schedule necessary service.. DATE OF SERVICE PERFORmED BY DESCRIPTION Page 15 VGZ-024 / 20120410.2 www.vogelzang.com BK150E /...
  • Page 16 “FOR GOD SO LOVED THE wORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT wHOEVER BELIEVES IN HIm SHALL NOT PERISH BUT HAVE ETERNAL LIFE” jOHN 3:16 mADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com...

Table of Contents