Vogelzang International BX22EL Owner's Manual
Hide thumbs Also See for BX22EL:

Advertisement

Quick Links

"Lit'l Sweetie" BOXWOOD STOVE
Model BX22EL Owners Manual
Le manuel de langue français est disponible à www.vogelzang.com
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS
ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
VGZ-003 / 20120224.1
EPA Exempt per Method 28A
(Save These Instructions)
French language manual is available at www.vogelzang.com
This stove meets test standards:
US: UL 1482-2011 & CDN: ULC-S627-00
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
EQUIPMENT INSTALLER!
DO NOT INSTALL IN A MOBILE HOME.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
Report No. 180-S-08b-2
BX22EL / Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Vogelzang International BX22EL

  • Page 1 “Lit’l Sweetie” BOXWOOD STOVE Model BX22EL Owners Manual EPA Exempt per Method 28A (Save These Instructions) Le manuel de langue français est disponible à www.vogelzang.com French language manual is available at www.vogelzang.com Report No. 180-S-08b-2 This stove meets test standards: READ ALL INSTRUCTIONS CAREFULLY US: UL 1482-2011 &...
  • Page 2: Safety Precautions

    firebox. This stove has not been APPLIANCE. tested with the use of grates, andirons or other 9. DO NOT CONNECT A WOOD BURNING STOVE means of elevating the fire and must not be used. Page 2 / BX22EL VGZ-003 / 20120224.1...
  • Page 3 29. DO NOT CONNECT TO OR USE IN CONJUNC- Coal and Wood Stoves Safely” NFPA No. HS-10- TION WITH ANY AIR DISTRIBUTION DUCT 1978. The address of the NFPA is Batterymarch WORK UNLESS SPECIFICALLY APPROVED Park, Quincy, MA 02269. VGZ-003 / 20120224.1 BX22EL / Page 3...
  • Page 4: Table Of Contents

    Parts – Lit’l Sweetie Boxwood ................ 16 Floor Protector Calculations ................17 NOTE: A PROFESSIONAL, LICENSED HEAT- ING AND COOLING CONTRACTOR MUST BE CONSULTED IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THIS SOLID FUEL BURNING APPLIANCE. Page 4 / BX22EL VGZ-003 / 20120224.1...
  • Page 5: Tools And Materials Required For Installation

    ASSEMBLY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of our wood stove and assumes no responsibility of any incidental or consequential damages. TOOLS REQUIRED MATERIALS REQUIRED (NOTE: The following items are NOT included with your stove)
  • Page 6: Locating The Stove

    MAY NOT BE REDUCED BY ANY MEANS IN USA ly place the stove in your selected location. OR CANADA. Install connector pipe, elbows, and thimble as continued on next page required, utilizing either a recently cleaned and Page 6 / BX22EL VGZ-003 / 20120224.1...
  • Page 7: Floor Protector, Minimum Clearances

    7PWL *VUULJ[VY [V *LPSPUN .......ã  JT 36"/91.4cm 8"/21cm CAUTION: KEEP FURNISHINGS AND OTHER (TOP VIEW) 27"/68.6cm COMBUSTIBLE MATERIALS AWAY FROM THE STOVE. Figure 8 – Top View Minimum Clearance Dimensions from Combustible Surfaces VGZ-003 / 20120224.1 BX22EL / Page 7...
  • Page 8: Connector Pipe Installation

    1/4˝(6.4mm) per foot COULD RESULT. of horizontal run. 3. You must have at least 18˝/457mm of clearance between any horizontal piping and the ceiling. CORRECT WRONG WRONG Figure 10 – Stovepipe/Flue Connections Page 8 / BX22EL VGZ-003 / 20120224.1...
  • Page 9: Chimney Connections/Draft

    5. C o n t a c t y o u r l o c a l b u i l d i n g a u t h o r i t y for approved methods of installation and any necessary permits and/or inspections. Figure 12 - Chimney Construction through Attic Space VGZ-003 / 20120224.1 BX22EL / Page 9...
  • Page 10 CAUTION: NOT ALL FIREPLACE CHIMNEYS ARE SUITABLE FOR CONVERSION TO AC- COMMODATE A WOOD STOVE. CHECK WITH Figure 14 - Chimney Connection to Firebox A QUALIFIED EXPERT. Through Masonry Wall continued on next page Page 10 / BX22EL VGZ-003 / 20120224.1...
  • Page 11 Positioning the center of the stove pipe entry into the chimney 24˝/61cm below the ceiling should insure proper clearance for a 6˝/152mm stovepipe. Figure 15 - Fireplace Conversion VGZ-003 / 20120224.1 BX22EL / Page 11...
  • Page 12: Chimney Connection Systems & Clearances

    24 gauge thickness. Fasten- ers used to secure chimney section shall not penetrate chimney flue liner. Page 12 / BX22EL VGZ-003 / 20120224.1...
  • Page 13: Operating Instructions

    fire will burn. The more open, the VICINITY OF THE STOVE — WHETHER IN USE faster and hotter the fire will burn. Do not over fire OR IN STORAGE. the stove. continued on next page VGZ-003 / 20120224.1 BX22EL / Page 13...
  • Page 14: Adding Fuel

    TRASH OR FLAMMABLE LIQUIDS MAY CAUSE 1. Creosote will inevitably form in your chimney and OVER FIRING. connector pipe. Following these steps will help reduce the rate of build up. continued on next page Page 14 / BX22EL VGZ-003 / 20120224.1...
  • Page 15: Creosote Formation, Prevention, Need For Removal

    Required Tune-up. This stove is manufactured with cast iron components. IT DOES NOT HAVE WELDED SEAMS. Periodic “tune up” may be required by refill- ing and/or replacing the cement/joint mortar along the seams where the cast iron components meet. VGZ-003 / 20120224.1 BX22EL / Page 15...
  • Page 16: Parts - Lit'l Sweetie Boxwood

    ORDERING PARTS - BX22EL BOXWOOD STOVE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustration and parts list provided to identify parts. Ref. Part Ref. Part Description Qty.
  • Page 17: Floor Protector Calculations

    Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem Step 4: Compare Rsystem to Rspecs Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative. VGZ-003 / 20120224.1 BX22EL / Page 17...
  • Page 18 “FOR GOD SO LOVED THE WORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT WHOEVER BELIEVES IN HIM SHALL NOT PERISH BUT HAVE ETERNAL LIFE” JOHN 3:16 MADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Page 18 / BX22EL VGZ-003 / 20120224.1...

Table of Contents