MODEL: VG5770 Certifi ed for installations in the USA and Canada. French version is available for download from the Vogelzang website: http://www.Vogelzang.com/ OWNER’S MANUAL PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS APPLIANCE. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
WARRANTY INFORMATION CARD Name__________________________________________ Telephone #: (_____)_____________ City____________________________________________ State_______ Zip_________________ Email Address __________________________________________________________________ Model # of Unit________________________________ Serial #___________________________ Fuel Type: Wood Coal Pellet Gas Other _________________________ Place of Purchase (Retailer)______________________________________________________ City____________________________________________ State_______ Zip_________________ If internet purchase, please list website address___________________________________ Date of Purchase _______________________________________________________________ Alternative Heat Main Heat Source...
Page 4
Fold Here Fold Here Fold Here PLACE STAMP HERE United States Stove Company P.O. Box 151 South Pittsburg, TN 37380...
Safety Precautions IMPORTANT: Read this entire manual before install- stances and a safety concern may arise from sparks or ing and operating this product. Failure to do so may fumes entering the room. result in property damage, bodily injury, or even death. ...
SPECIFICATIONS Heating Specifi cations Fuel Burn Rate* (lowest setting) 1.5 lbs./hr. (0.5 kg/hr) Burn Time (lowest setting) 40 hrs. (approximate) Hopper Capacity 60 lbs. (55kg) * Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results. Dimensions Height 44.5 in.
INSTALLATION INSTALLATION OPTIONS Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result in property damage, bodily injury, or even death! (See specifi c installation details for clearances and other installation requirements) A Freestanding Unit—supported by pedestal/legs and placed on a non-combustible fl...
Installation FLOOR PROTECTION This heater must have a non-combustible fl oor protector (ember protection) installed beneath it if the fl oor is of com- bustible material. If a fl oor pad is used, it should be UL listed or equal. The fl oor pad or non-combustible surface should be large enough to cover at least the area under the product and 6 in.
Installation VENTING REQUIREMENTS Install vent at clearances specifi ed by the vent manufacturer. Do not connect the pellet vent to a vent serving any other appliance or stove. Do not install a fl ue damper in the exhaust venting system of this unit. ...
Installation VENT TERMINATION CLEARANCES: Minimum 4-foot (1.22m) clearance below or beside any door or window that opens. Minimum 1-foot (0.3m) clearance above any door or window that opens. Minimum 3-foot (0.91m) clearance from any adjacent building. Minimum 7-foot (2.13m) clearance from any grade when adjacent to public walkways. Minimum 2-foot (0.61m) clearance above any grass, plants, or other combustible materials.
Installation THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION) Canadian installations must conform to CAN/CSA-B365. To vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter. If the exhaust adapter is at least 18 in.(457mm) above ground level, a straight section of pellet vent pipe can be used through the wall.
Installation OUTSIDE AIR SUPPLY (optional, unless installing in a mobile home) Adequate ventilation air is required to operate this heater. During operation, the heater draws air for combustion which can be assisted by the installation of outside combustion air inlets. However, certain weather conditions such as icing or use of kitchen exhaust fans may impact and reduce the effectiveness of vents.
Control Panel PANEL CONTROLS The blowers and automatic fuel supply are controlled from a panel on the top of the VG5770. The control panel func- tions are a follows. ON/OFF SWITCH (“POWER” BUTTON) • When pushed, the stove will automatically ignite. No other fi re starter is necessary. The igniter will stay on for at least 10 and up to 12 minutes, depending on when Proof of Fire is reached.
Clean door glass if necessary (a dry cloth or paper towel is usually suffi cient). Never use abrasive cleaners on the glass or door. Check fuel in the hopper, and refi ll if necessary. NOTE: The VG5770 Hopper can hold up to 60 lbs. of pellets. BUILDING A FIRE Never use a grate or other means of supporting the fuel.
Operation chimney. You should adjust the damper based on the fi re’s appearance. A low, reddish, dirty fi re can be improved by turning the dampener slightly to the right. A “blow torch” fi re can be improved by turning the dampener to the left a little bit. As a general rule, on lower feed rate settings, the damper should be farther to the left closing it off.
Maintenance Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards. Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust system for any inspection, cleaning, or maintenance work. ...
Maintenance GLASS - Cleaning, Removal and Replacement of Broken Door Glass Cleaning - We recommend using a high quality glass cleaner. Should a buildup of creosote or carbon accumulate, you may wish to use 000 steel wool and water to clean the glass. DO NOT use abrasive cleaners. DO NOT perform the cleaning while the glass is HOT.
Trouble Shooting Guide When your stove acts out of the ordinary, the fi rst reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems encountered are often the result of only fi ve factors: 1) poor fuel;...
Page 19
Trouble Shooting Guide Display is Flashing “E2” Possible Causes Possible Remedies: (Unplug stove fi rst when possible) Unhook air hose from the air switch and blow through it. 1. Airfl ow switch hose or stove attachment pipes for hose If air fl ows freely, the hose and tube are fi ne. If air will not are blocked.
Trouble Shooting Guide Display is Flashing “E3” Possible Causes Possible Remedies: (Unplug stove fi rst when possible) 1. The hopper is out of pellets Refi ll the hopper. If on the low setting, you may need to close the damp- 2.
Page 21
Trouble Shooting Guide Display is Flashing “E4” Possible Causes Possible Remedies: (Unplug stove fi rst when possible) 1. The air inlet, burnpot, interior combustion air chambers, Follow all cleaning procedures in the maintenance sec- combustion blower, or exhaust pipe are blocked with ash tion of the owner’s manual.
Page 22
Trouble Shooting Guide STOVE FEEDS PELLETS, BUT WILL NOT IGNITE Possible Causes: Possible Remedies: (Unplug stove fi rst when possible) Air damper open too far for ignition. Push the air damper in closer to the side of the stove for startup. In some situations it may be necessary to have the damper completely closed for ignition to take place.
Trouble Shooting Guide STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes: Possible Remedies: (Unplug stove fi rst when possible) High limit switch has tripped or is defective. Wait for the stove to cool for about 30 - 45 minutes. Locate the High Limit thermodisc and press the reset button on the back of it.
Page 24
Trouble Shooting Guide • GLASS “SOOT’S” UP AT A VERY FAST RATE • FLAME IS LAZY, DARK, AND HAS BLACK TIPS • AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Causes: Possible Remedies: (Unplug stove fi rst when possible) Stove or vent pipe is dirty, which restricts airfl...
Page 28
How to Order Repair Parts THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR PELLET STOVE, AND ENABLE YOU TO ORDER REPAIR PARTS COR- RECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
Need help?
Do you have a question about the VG5770 and is the answer not in the manual?
Questions and answers