Locating Stove; Duct System - Vogelzang International PB65XL Owner's Manual

Railroad potbelly stove
Hide thumbs Also See for PB65XL:
Table of Contents

Advertisement

lOCATINg STOvE

DASHED LINE SHOWS
HORIZONTAL CHIMNEY
CONNECTOR AND
ADDITIONAL FLOOR
PROTECTION REQUIRED
18"
SIDEWALL
COMBUSTIBLE
CONSTRUCTION
ACCORDING TO
NFPA 211
36"
18"
54"
Fig. 2
Proper clearances must be maintained for adequate
air circulation. Adequate ventilation must be
provided while operating this stove.
1. The stove must be placed on solid con-
crete, solid masonry, or on an listed
floor protector, such as Hy-C or Impe-
rial Model UL 5463BK when installed on a
combustible floor. The base must extend at
least 18" beyond the front, rear and sides of the
stove, and must extend under the stove pipe if
it is elbowed towards a wall (see figure 5 and
consult local building codes and fire protection
ordinances.)
2. The stove must have its own flue. DO NOT
CONNECT THIS UNIT TO A CHImNEY
FLUE SERVING OTHER APPLIANCES.
3. After observing the clearances to combustible
materials (figure 2 – 4), locate your floor
protector accordingly (figure 2) and care-
fully place the stove in your selected location.
Install stove pipe, stove pipe damper, elbows,
and thimble as required, utilizing either a
recently cleaned and inspected 6" masonry
chimney or a 6" i.d. listed chimney. Maximum
64 square inches.
CORNER CLEARANCES
36"
36"
Minimum Corner Clearances from
Combustible Surfaces
Page 4
/ PB65XL
BACKWALL
36"
COMBUSTIBLE
CONSTRUCTION
ACCORDING TO
NFPA 211
FLOOR
PROTECTOR
63"
18"
18"
(TOP VIEW)
Minimum Clearance Dimensions from Combustible Surfaces
Fig. 4 – Top View
4. Use 6" round black stove pipe. DO NOT use
galvanized duct pipe. Secure pipe sections with
three (3) sheet metal screws in each stove pipe
and/or elbow joint to firmly hold the pipe sec-
tions together. DO NOT CONNECT THIS
STOVE TO ANY AIR DISTRIBUTION OR

DUCT SYSTEm.

5. R e c h e c k c l e a r a n c e s f r o m t h e s t ove ,
connector stove pipe, and corner clearances
using the illustrations (figure 2, 3 & 4) and
your local building codes or fire protection
ordinances.
NOTE: Drywall faced with brick or stone must
be considered a combustible surface.
6. D O N OT I N S TA L L T H I S S TOV E
IN A mOBILE HOmE, TENT OR TRAILER.
(NO EXCEPTIONS)
7. The clearances provided are minimum
dimensions. Installation of this stove must
comply with your local building code rul-
ings.
8. This stove is NOT a UL listed stove.
MiniMuM ClearanCes
To CoMbusTible surfaCes
unit to sidewall ....................................36 inches
unit to backwall ...................................36 inches
unit Corner to Wall ................................36 inches
Pipe Connector to backwall ......................38 inches
Pipe Connector to Ceiling ........................18 inches
Fig. 3
Continued on next page
VGZ-003 / 20110524.0