Miele CS 1018 Operating And Installation Instructions page 35

Gas hob
Table of Contents

Advertisement

Safety distances to the sides of the
hob
Ideally the hob should be installed with
plenty of space on either side. There
may be a wall at the rear and a tall unit
or wall at one side. On the other side,
however, no unit or divider should stan-
d higher than the hob (see illustrations).
Due to the high temperatures radiated
by the hob, it is essential that a
minimum distance of 50 mm is
maintained between the worktop
cut-out and the back wall.
The minimum distance a between the
worktop cut-out and a wall or tall unit to
the right or left of it is:
40 mm
for
CS 1212 / CS 1212-1
CS 1221
CS 1234 / CS 1234-1
CS 1223
50 mm
for
CS 1112
CS 1122
CS 1134
CS 1326 / CS 1327
CS 1411
100 mm for
CS 1012 / CS 1012-1
CS 1013 / CS 1013-1
150 mm for
CS 1421
CS 1312
CS 1322
200 mm for
CS 1034 / CS 1034-1
250 mm for
CS 1011
CS 1018
CS 1021
CS 1028
Safety instructions for installation
recommended
not recommended
not allowed
35