To Check The First Intake Of Air - Miele CS 1018 Operating And Installation Instructions

Gas hob
Table of Contents

Advertisement

To check the first intake of air

a Retaining nut
b Air intake sleeve
Gap X must measure:
For Town Gas:
For Natural Gas:
For Liquid Petroleum Gas :
Conversion to another type of gas
If it does not:
– Loosen the retaining nut, adjust the
air intake sleeve, and tighten the
retaining nut again.
– Finally secure the jet against
inadvertent loosening with sealing
wax.
– Reassemble the hob in the reverse
order.
The flame must not go out on the lowest
setting, or when the control is turned
quickly from a high to a low setting.
On the highest setting the flame must
have a distinctive and visible core.
13 mm
6 mm
13 mm