10 – Camera program
Label
Trigger
LCD intensity
Auto power off
10
Display power off
➲ For protective reasons, the LCD will be switched off if the detector temperature
exceeds +60 °C (+149 °F) and the camera will be switched off if the detector temper-
ature exceeds +68 °C (+154.4 °F)
86
Value
Laser
■
Save
■
Disabled
■
One-shot autoadjust
■
Update ref. temp.
■
Low intensity of the
■
LCD
Medium
■
High
■
None
■
2 min
■
5 min
■
10 min
■
None
■
30 sec.
■
60 sec.
■
2 min.
■
Explanation
Select Laser to activate the laser when pulling
■
the trigger
Select Save to save the current image when
■
pulling the trigger
Select Disabled to disable the trigger
■
Select One-shot autoadjust to autoadjust the
■
camera when pulling the trigger
Select Update ref. temp to update the reference
■
temperature when pulling the trigger
If Update ref. temp. is selected:
By pulling the trigger for more than 1 second, a
dialog displaying the message Restart ref temp
at nn.n °C? will appear.
Do one of the following:
Select OK to purge the internal camera buffer
■
and begin a new sampling sequence
Select Cancel to leave the dialog box
■
Select Low to set the LCD intensity to the lowest
■
level
Select Medium to set the LCD intensity to
■
medium level
Select High to set the LCD intensity to the
■
highest level
If the camera is switched on but currently not used,
it will automatically be switched off after a specified
time.
Set the time by pressing the navigation pad
left/right.
If the camera is switched on but currently not used,
the display will automatically be switched off after
a specified time.
Set the time by pressing the navigation pad
left/right.