1.6

Replacing a Power Switch or Indicator Lamp

1. Unplug the power cord.
2. Remove the two screws on the bottom of the faceplate. Pull out and lift up slowly. Note that
when lowering the faceplate, the door will lower and swing out to be set aside.
3. Mark wires for reattachment as you disconnect them.
4. Remove the old switch or lamp.
5. Install new switch or lamp and reassemble in reverse order.
1.7

Replacing a Temperature Probe or High-Limit Thermostat

1. Unplug the power cord.
2. Drain the cooking oil from the frypot and leave the drain open.
3. Remove the two screws from the top control box cover.
4. Remove the screws from the back fryer cover.
5. If replacing the temperature probe, disconnect the wire plug containing the probe wiring.
6. Using an open end wrench, loosen the temperature probe or high-limit probe. Pull the probe
through the hole and remove the probe.
7. If replacing the high-limit thermostat, remove the two screws that attach the high-limit reset
switch to the control box. Remove the two wires attached to the high-limit reset switch. Pull the
probe through the bushing in the rear of the control box. Attach new high-limit reset switch to
the control box and reattach wires. Thread through the bushing in the rear of the control box.
8. Thread the new probe through the proper hole in the rear of the frypot. Ensure that the probe is
aligned with the holes on the bracket attached to the element.
9. Apply Loctite PST567 sealant to replacement threads.
10. Screw the replacement probe into the frypot and tighten 170-180 inch-pounds torque. DO NOT
OVERTIGHTEN.
11. Reattach the connector and reassemble in reverse order.