SUPER RUNNER SERIES ELECTRIC FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.1

General

Before performing any maintenance on your Dean Super Runner Electric fryer, you must disconnect
the electrical power supply.
When electrical wires are disconnected, it is recommended that they be marked in such a way as to
facilitate re-assembly.
Hot oil will cause severe burns. Never attempt to move this appliance when filled with hot
oil, or to transfer hot oil from one container to another.
This equipment should be unplugged when servicing, except when electrical circuit tests are
required. Use extreme care when performing such tests.
Inspection, testing and repair of electrical components should be performed by an
1.2
Temperature Control Knob Calibration
If the temperature controller knob requires adjustment, do the following:
1. Set the temperature controller dial to the desired oil temperature and wait for the temperature to
stabilize.
2. When the oil temperature reaches operating temperature, let the heating elements cycle at least
four times (indicated by the HEAT light going out and coming back on).
3. Insert a thermometer or pyrometer probe near the temperature-sensing probe approximately three
inches deep into the oil. When the heating elements cycle on for the fourth time, the temperature
should read within ± 5°F (± 3°C) of the temperature control knob setting.
4. Loosen the knob setscrew and rotate the knob to the correct temperature setting on the faceplate.
5. Check the temperature again with a high-quality immersion thermometer to confirm that the
setting is correct.
6. Re-tighten the knob setscrew at the calibrated position.
DANGER
DANGER
Disconnect all power cords before servicing.
authorized service agent only.
1-1