Flir E5 - FLIR EX series User Manual

Hide thumbs Also See for EX series:
Table of Contents

Advertisement

8
Technical data

8.4 FLIR E5

P/N: 63905-0501
Rev.: 22369
General description
The FLIR Ex series cameras are point-and-shoot infrared cameras that give you access to the infrared
world. A FLIR Ex series camera is an affordable replacement for an infrared thermometer, providing a
thermal image with temperature information in every pixel. The new MSX and visual formats make the
cameras incomparably easy to use.
The FLIR Ex series cameras are user-friendly, compact, and rugged, for use in harsh environments.
The wide field of view makes them the perfect choice for building applications.
Benefits:
Easy to use: The FLIR Ex series cameras are fully automatic and focus-free with an intuitive inter-
face for simple measurements in thermal, visual, or MSX mode.
Compact and rugged: The FLIR Ex series cameras' low weight of 0.575 kg and the accessory belt
pouch make them easy to bring along at all times. Their rugged design can withstand a 2 m drop
test, and ensures reliability, even in harsh environments.
Ground breaking affordability: The FLIR Ex series cameras are the most affordable infrared cameras
on the market.
Imaging and optical data
IR resolution
Thermal sensitivity/NETD
Field of view (FOV)
Minimum focus distance
Spatial resolution (IFOV)
F-number
Image frequency
Focus
Detector data
Detector type
Spectral range
Image presentation
Display
Image adjustment
Image presentation modes
Image modes
Multi Spectral Dynamic Imaging (MSX)
Measurement
Object temperature range
Accuracy
Measurement analysis
Spotmeter
Area
Emissivity correction
#T559828; r.18043/22369; en-US
120 × 90 pixels
<0.10°C (0.27°F) / <100 mK
45° × 34°
0.5 m (1.6 ft.)
6.9 mrad
1.5
9 Hz
Focus free
Focal plane array (FPA), uncooled
microbolometer
7.5–13 µm
3.0 in. 320 × 240 color LCD
Automatic adjust/lock image
Thermal MSX, Thermal, Thermal blending, Digital
camera.
IR image with enhanced detail presentation
–20°C to +250°C (–4°F to +482°F)
±2°C (±3.6°F) or ±2% of reading, for ambient tem-
perature 10°C to 35°C (+50°F to 95°F) and object
temperature above +0°C (+32°F)
Center spot
Box with max./min.
Variable from 0.1 to 1.0
27