[ 11 ] LCD test

[Function]
This test will check the LCD display.
In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera-
tor.
The display can be switched by the touch of the panel. The display will not change to the next
one unless the panel is touched.
[Operation]
Press [OK] key or [NG] key to end the test when performing one time check.
"OK" = 1, "NG" = 9
Operation :
n
n: 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press "ESC" key)
[LCD]
Black
White
Touch any place
in the panel.
Shows the following colors and patterns in the display in the order of black, white, red, green,
blue, check and reverse check.
Returns to the normal display after the test, and waits for the input of [OK] or [NG] by the operator (in
case of one time check).
In case of continuous check, the test is ended manually upon the input of [ESC] key.
LCD
n021
LCD
OK
END
n021
[PRINT]
LCD
n021
LCD
OK
END
n021
0
2
1
ST
Red
Touch any place
Touch any place
in the panel.
in the panel.
— 35 —
Green
Blue
Touch any place
Touch any place
in the panel.
in the panel.
Reverse
Check (black
and white)
check
Touch any place
in the panel.