Diag Command Input System; Status Display - Casio QT-6100 Service Manual

Hide thumbs Also See for QT-6100:
Table of Contents

Advertisement

7-3. DIAG command input system

Input a command according to the following code.

7-4. Status Display

With the EX820, the following display is displayed
on the LCD (SVGA). (In this DIAG, the display
area is divided into a display for register entry and
a display of DIAG results and so forth.
[Functions]
Status is displayed for those devices having status information. The devices and status dis-
played are as shown below.
Device
Dallas key
Dallas key 2
Drawer
MAC address
CF
DISP ON/OFF switch
TEMP
[LCD Display]
MAC ADRS
XX-XX-XX-XX-XX-XX
CF INSERT
DISP ON/OFF
ON
Diag Ver : XXXXXX XXXX
DALLAS
DRW1 CLOSE
0000
Counter display
* Addition of TEMP information and DISP ON/OFF status
The TEMP status is acquired preferentially when the DISP ON/OFF switch is ON. When meas-
uring other status information or when starting each test mode, always make sure to begin after
switching off the DISP ON/OFF switch.
Status Information (Displayed Information)
Dallas key no.
Dallas key no.
Open/close status
MAC address
Insertion status
Switch status
Power supply A/D conversion value
* Display only updated when DISP ON/OFF switch is ON
TEMP 20
Status information is displayed continuously (in ordinary characters).
However, when performing a test, the status at completion of a test is
displayed following completion of that test.
DRW2 CLOSE
1234
Register: Characters enlarged 1.5 times (max. 10 digits)
— 28 —
X X X X X X n
XXXXXX : additional action
n : number of times
a : action
g : group
d : device number
DALLAS
MENU SHEET 1
DRW1 CLOSE
DRW2 CLOSE
0000
a
g
d
CLR
ESC
7
8
9
4
5
6
1
2
3
0
ST

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents