Online Interface - Casio QT-6100 Service Manual

Hide thumbs Also See for QT-6100:
Table of Contents

Advertisement

6-2. Online interface

Only the RS-232C Com1 port can be connected with a modem or perssonal computer.
Direct connection to PC
Connection layout
Note: Maximum 3 remote printers in the 1
terminal system, 6 remote printers / 2
terminal system, 8 remote printers in
the 3 ~ 32 terminal can be defined.
PC Cable wiring
MODEM system
Connection layout
Note: Maximum 3 remote printers in
the 1 terminal system, 6 remote
printers / 2 terminal system, 8
remote printers in the 3 ~ 32
terminal can be defined.
PC Cable wiring
Via COM 1 port of the master terminal
or Inline (Ethernet)
QT-6100 (Com1)
Pin No. Signal name
3
SD/TXD
2
RD/RXD
7
RS/RTS
8
CS/CTS
1
CD/DCD
4
ER/DTR
6
DR/DSR
9
CI/RI
5
GND
PC
QT-6100 (Com1)
Pin No. Signal name
3
SD/TXD
2
RD/RXD
7
RS/RTS
8
CS/CTS
1
CD/DCD
4
ER/DTR
6
DR/DSR
9
CI/RI
5
GND
— 26 —
PC
Maximum 32 terminals
PC
Pin No.
Pin No.
Signal name
(DSUB9) (DSUB25)
3
2
2
3
7
4
8
5
1
8
4
20
6
6
-
22
5
7
on-line
Maximum 32 terminals
MODEM (DSUB25)
Pin No. Signal name
2
SD
3
RD
4
RS
5
CS
8
CD
20
ER
6
DR
22
CI
7
GND
SD
RD
RS
CS
CD
ER
DR
C
GND

Hide quick links: