2.5.1

Connect Power

Please refer to the illustrations below to connect power core through the supplied power adaptor.
2.5.2

Connect Ethernet Cable

Use of Category 5 Ethernet cable is recommended for network connection; to have best
transmission quality, cable length shall not exceed 100 meters. Connect one end of the Ethernet cable
to the RJ-45 connector of the network Speed Dome Camera, and the other end of the cable to the
network switch or PC.
NOTE: In some cases, you may need use an Ethernet crossover cable when connecting
the network Speed Dome Camera directly to the PC.
Note
Check the status of the link indicator and activity indicator LEDs; if the LEDs are unlit, please check
LAN connection.
2.5.3

Apply Alarm I/O

The network Speed Dome Camera supports 4 digital alarm inputs and 2 digital alarm outputs.
Please make sure the alarm connections are properly wired before starting to configure alarm related
settings on this "Application" page. Please refer to the pin definition table below for alarm system wiring.
Pin
ALARM_O
1
ALARM_OUT_NC_1
2
ALARM_OUT_COM_1
3
GND
4
ALARM_OUT_NO_2
5
ALARM_OUT_NC_2
6
2.5.4

Apply Audio

Please refer to the illustrations below to set up the audio according to the Audio pin definition.
Pin
Definition
AC 24_1
1
FG
2
AC 24_2
3
Green Link Light indicates good network connection.
Orange Activity Light flashes for network activity indication.
Definition
UT_NO_1
Pin
ALARM_OUT_COM_2
7
GND
8
ALARM
9
ALARM_IN_3
10
ALARM_IN_2
11
12
ALARM_IN_1
- 19 -
Definition
_IN_4