troubleshooting
warnings
For information about warnings, refer to the following table. The messages are displayed flashing (alternating between
temperature and the message).
warnings
inforMation
Gas ignition failed. The gas flame has not been ignited after 45 seconds. Turn refrigerator OFF and
LP
then back ON to return to normal operation.
Gas bottle empty and needs replacing or burner jet is clogged and should be cleaned.
Air in the gas line? After changing a gas bottle or after a long shutoff period, the gas line is likely to
be filled with air. You may have to repeat the lighting procedure (45 seconds) by turning the refrig-
erator off and on several times in order to purge the air out of the gas lines.

error coDes

For information about error codes, refer to the following table. The codes are displayed by flashing temperature setting LEDs.
After having solved the problem, turn refrigerator OFF and then back ON. The refrigerator will return to normal operation.
error coDes
Disconnected gas valve or hardware fault in the gas operation system.
A faulty temperature sensor device or a fault in the associated electronic circuitry has occurred.
Make sure the sensor wire is connected.
DC voltage is out of range (exceeds or drops below the limit values approx. 8-18V DC).
No communication between display and power module.
inforMation
Overheating thermostat is disconnected.
The cooling unit has been overheated. Service is required.
- 19 -