Troubleshooting; Error Codes - Dometic RM3762 Operating Instructions Manual

Hide thumbs Also See for RM3762:
Table of Contents

Advertisement

TROUBLESHOOTING

ERROR CODES

For information about error codes, refer to the following table. The codes are displayed flashing (alternating between tem-
perature and message). If an error code is displayed, contact a Dometic dealer or Service Center.
After having solved the problem, turn refrigerator OFF and then back ON. The refrigerator will return to normal operation.
ERROR CODES
E0
E1
E2
E3
E4
INFORMATION
No communication between display and power module.
Disconnected LP gas valve or hardware fault in the LP gas operation system. The refrigerator
may still be operational on 120 VAC.
A failure of the temperature sensor device or associated electronic circuitry has occurred. Make
sure the sensor wire is connected.
The cooling unit has malfunctioned. Contact a Service Center.
DC voltage is out of range (exceeds or drops below the limit values, approximately 8-18 VDC).
13