Error Codes - Dometic RM3762 User Manual

Refrigerator for lp-gas & electric operation
Hide thumbs Also See for RM3762:
Table of Contents

Advertisement

tRoUblEShooting & diagnoStic tESt
warnings
For information about warnings, refer to the following table. The messages are displayed flashing (alternating between
temperature and the message).
warnings
information
Gas ignition failed. Gas bottle empty or burner jet clogged.
LP

Error codes

For information about error codes, refer to the following table. The codes are displayed flashing (alternating between temperature
and message).
Error code
information
No communication between display and power modules.
E 0
The control system will revert to full automatic operation selecting the best energy source available with aC,
Gas priority. The temperature setting will be maintained at the mid positions. The power module will con-
tinually attempt to reestablish operation of the display module.
Hardware fault in the gas operation system.
E 1
a failure of the temperature sensor device or associated electronic circuitry has occurred.
E 2
If the connection to the temperature sensor is faulty, the cooling unit runs continuously after 30 seconds delay
at power on.
- 12 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm3962

Table of Contents