troubleshooting
warnings
For information about warnings, refer to the following table. The messages are displayed flashing (alternating between
temperature and the message).
warnings
information
Gas ignition failed. The gas flame has not been ignited after 45 seconds. Turn refrigerator OFF and then
back ON to return to normal operation.
Gas bottle empty and needs replacing or burner jet is clogged and should be cleaned.
LP
Air in the gas line? After changing a gas bottle or after a long shutoff period, the gas line is likely to be filled
with air. you may have to repeat the lighting procedure (45 seconds) by turning the refrigerator off and on
several times in order to purge the air out of the gas lines.

error codes

For information about error codes, refer to the following table. The codes are displayed flashing (alternating between temperature
and message).
error codes
e0
e1
e2
E3
e4
information
No communication between display and power module.
Disconnected gas valve or hardware fault in the gas operation system.
A failure of the temperature sensor device or associated electronic circuitry has occurred.
Make sure the sensor wire is connected.
Overheating thermostat is disconnected.
The cooling unit has been overheated. Service is required.
DC voltage is out of range (exceeds or drops below the limit values approx. 8-18V DC).