CONVERSION TO NATURAL GAS OR TO LPG
REPLACEMENT
INJECTORS OF THE TOP BURNERS
If the injectors are not supplied they can
be obtained from the After-Sales Service.
Select the injectors to be replaced
according to the "Table for the choice of the
injectors".
To replace the injectors proceed as follows:
Remove pan supports and burners
from the cooktop.
Using a wrench, substitute the nozzle
injectors "J" (figs. 10.4, 10.5) with
those most suitable for the kind of gas
for which it is to be used.
The burners are conceived in such a
way so as not to require the regulation
of the primary air.
ADJUSTING OF THE MINIMUM OF
THE TOP BURNERS
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even with a quick turn from the
maximum position to that of minimum.
The flame adjustment is done in the
following way:
Turn on the burner.
Turn the tap to the MINIMUM position.
Take off the knob.
With a thin screwdriver turn the screw
"F" until adjustment is correct (fig.
10.6).
Normally for LPG, tighten up the
regulation screw.