Kenwood CK 405 G Instructions For Use - Installation Advice page 33

Kenwood ck 405 g double oven gas cooker
Table of Contents

Advertisement

GAS CONNECTION
The installation of the gas appliance to Natural Gas or LP Gas must be carried out by a
suitably qualified and registered installer.
Installers shall take due account of the provisions of the relevant British Standards Code of
Practice, the Gas Safety Regulations and the Building Standards (Scotland) (Consolidation)
Regulations issued by the Scottish Development Department.
Installation to Natural Gas
Installation to Natural Gas must conform to the Code of Practice, etc.
The supply pressure for Natural Gas is 20 mbar.
The installation must conform to the relevant British Standards.
Installation to LP Gas
When operating on Butane gas a supply pressure of 28-30 mbar is required.
When using Propane gas a supply pressure of 37 mbar is required.
The installation must conform to the relevant British Standards.
Warning: Only a suitably qualified and registered installer, also with technical knowledge
of electricity should install the appliance.
He should observe the Regulations and Codes of Practice governing such installation of
gas appliances.
Note: It is recommended that the gas connection to the appliance is installed with a flexible
connecting tube made to BS5386.
Notes:
Flexible hoses can be used where the sited ambient temperature of the hose
does not exceed 70°C. These hoses must be manufactured in accordance with
BS669 part 1 and be of the correct construction for the type of gas being used.
Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas
(LPG gas hoses can be identified by a either a red band or stripe on the rubber
outer coating of the hose).

The hose should not be crushed or trapped or be in contact with sharp or
abrasive edges.
Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one
at a time by brushing the solution over the connection.
The presence of bubbles will indicate a leak.
If there is a leak, tighten the fitting and then recheck for leaks.
IMPORTANT!
Do not use a naked flame to test for leaks.
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents