Hitachi Kokusai Electric HV-F202GV Installation Manual page 21

High pixel 3ccd camera
Table of Contents

Advertisement

2. Commands for acquisition image
(1) WIDTH MAX : Maximum width of the image
Command name
Address
Values (read only)
(2) HEIGHT MAX : Maximum height of the image
Command name
Address
Values (read only)
(3) WIDTH : Set the actual image width
Command name
Address
Values (Factory setting 1600)
(4) HEIGHT : Set the actual image height
Command name
Address
Values (Factory setting 1200)
(5) OFFSET : Setting of start position of the actual image
・OFFSET X : Set the horizontal offset
Command name
Address
Values (Factory setting 0) : 0 to (WIDTH MAX - WIDTH + 2)
・OFFSET Y : Set the vertical offset
Command name
Address
Values (Factory setting 0) : 0 to (HEIGHT MAX - HEIGHT + 2)
(6) PIXEL FORMAT : Set the pixel format
Command name
Address
Values
: WidthMax (Integer / Standard)
: A002F008 h
: 1600
: HeightMax (Integer / Standard)
: A002F00C h
: 1200
: Width (Integer / Standard)
: A0020000 h
: 2 to WIDTH MAX
: Height (Integer / Standard)
: A0020004 h
: 2 to HEIGHT MAX
: OffsetX (Integer / Standard)
: A0020008 h
: OffsetY (Integer / Standard)
: A002000C h
: PixelFormat (Enumeration / Standard)
: A0020014 h
: *Refer the following table
Set the actual image width at intervals of 2 pixels.
Set the actual image height at intervals of 2 pixels.
Set the horizontal start position of the actual image at intervals of
2 pixels.
Set the vertical start position of the actual image at intervals of
2 pixels.
Following format is available
Format
Mono8
Mono10
Mono12
RGB8Packed
BGR8Packed
RGB10V1Packed
RGB12Packed
YUV422Packed
YUV422_10Packed
YUV422_12Packed
Values
01080001
16
01100003
16
01100005
16
02180014
16
02180015
16
0220001C
16
0218001A
16
0210001F
16
80180001
16
80180002
16
8

Advertisement