Hitachi Kokusai Electric KP-M1A Operation Manual

B/w ccd camera

Advertisement

Quick Links

KP-M1A
B/W CCD Camera
Operation Guide
Aug 2001
KP-M1A
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi Kokusai Electric KP-M1A

  • Page 1 KP-M1A B/W CCD Camera Operation Guide Aug 2001 KP-M1A - 1 -...
  • Page 2: Table Of Contents

    Arrangement of internal switches External synchronization Field on demand function Timing chart 10. Electronic shutter 11. Connection 12. Optical system 13. Composition 14. External view 15. Optional accessories 16. Notes to users Attachment Spectral sensitivity characteristic KP-M1A - 2 -...
  • Page 3: General

    1. General The KP-M1A is a black and white camera using the latest high grade CCD having a 2/3-inch image size. The KP-M1A features high sensitivity, high resolution and high performance. The KP-M1A is provided with various functions including the multiple step electronic shutter function, field-on-demand function, integration mode switching function, HD/VD pulse switching function and non-interlaced scanning function.
  • Page 4: Specifications

    0.3Lx, fl.4, AGC:ON, GAMMA:ON, W/O IR cut filter (15) Signal-to-noise ratio 56dB (16) Electronic shutter 1/10000, 1/4000, 1/2000, 1/1000, 1/500, 1/250, 1/125, 1/120(CCIR), 1/100(EIA)sec OFF :Normal exposure Settable from external switch. Set to OFF at factory. KP-M1A - 4 -...
  • Page 5 Storage :-20 to 60 ,70%RH or less (25) Anti-vibration 98 m/s (10 to 60Hz,amplitude:0.98mm constant 60 to 200Hz amplitude, variable) (10 to 200Hz, sweep:1 min, XYZ,duration:30mm.) (26) Anti-vibration 686 m/s (Once each, top/bottom/left side/right side) (27) Dimensions 44(W)×29(H)×72(D)mm (28) Mass 120g approx. KP-M1A - 5 -...
  • Page 6: Name Of Each Section

    (4) FIELD/FRAME integration select switch Use this switch to select an integration mode. This switch is set to FRAME at factory. (5) SHUTTER ON/OFF switch Set the SHUTTER ON/OFF switch to ON to establish the shutter mode. KP-M1A - 6 -...
  • Page 7: Signal Connection To Dc In/Sync Connector

    The video signal cannot be fed simultaneously from both the VIDEO OUT connector and the DC IN/SYNC connector. If both the outputs are connected simultaneously, a proper picture cannot be obtained. Supply 12V DC in range between 11 and 13V. KP-M1A - 7 -...
  • Page 8: Arrangement Of Internal Switches

    6. Arrangement of internal switches Internal controls KP-M1A - 8 -...
  • Page 9 Clips a video level. Set to 1.0Vp-p. (Max: 1.2Vp-p) W.SUP control Prevents white compression of a video signal and extends a dynamic range. Effective when a video level is approximately 120% (Gamma: 1.0). (Approx. 110% for Gamma: ON) KP-M1A - 9 -...
  • Page 10: External Synchronization

    ! Horizontal drive signal (HD) T=1/f(H) T=1/f(V) 2 6Vp-p 2 6Vp-p Approx. 6.7µs Approx. 0.6ms(EIA); 0.5ms(CCIR) ! HD and VD phase relationship Set HD and VD fallings edges to the same phase (0 ± 5 µs) KP-M1A - 10 -...
  • Page 11: Field On Demand Function

    8. Field on demand function The KP-M1A is provided with the Field-on-Demand function to record a picture obtained at an optional timing by triggering to an image memory, etc. Four modes are switchable by the internal switch. 1) ONE trigger mode...
  • Page 12 (Fixed shutter) pulse Reset sync signal and start of shutter R/R function: The desired image is after one field with respect to the input pulse. FD function: The desired image is immediately after the input pulse. KP-M1A - 12 -...
  • Page 13 (3) Timing diagram KP-M1A - 13 -...
  • Page 14 Only one field image is delivered by one trigger pulse, and a sync signal lasts till the next pulse. Trigger pulse * 5Vp-p +0.5/-1.0Vp-p * Low period: EIA: 16.7ms or more CCIR: 20ms or more * High period: 8us or more KP-M1A - 14 -...
  • Page 15 * 5Vp-p +0.5/-1.0Vp-p * Trigger A: Low period: EIA: 63.5us or more CCIR: 64us or more High period: EIA: 16.7ms or more CCIR: 20ms or more * Trigger B: Low period: Not specified High period: 8us or more KP-M1A - 15 -...
  • Page 16 Trigger pulse * 5Vp-p +0.5/-1.0Vp-p * Low period: EIA: 63.5us or more CCIR: 64us or more * High period: EIA: 16.7ms or more CCIR: 20ms or more KP-M1A - 16 -...
  • Page 17 When the trigger B pulse is not supplied the normal exposure results. The V.SYNC pulse of the camera is not reset. Trigger pulse * 5Vp-p +0.5/-1.0Vp-p * Low period: Not specified * High period: 8us or more KP-M1A - 17 -...
  • Page 18: Timing Chart

    9. Timing chart KP-M1A - 18 -...
  • Page 19 KP-M1A - 19 -...
  • Page 20 KP-M1A - 20 -...
  • Page 21 KP-M1A - 21 -...
  • Page 22 KP-M1A - 22 -...
  • Page 23 KP-M1A - 23 -...
  • Page 24: Electronic Shutter

    The higher the shutter speed, the greater the effect. However, since sensitivity lower, adjust the lens iris or increase illumination. And when the shutter is used, the flicker of an object may be emphasized. Use a light which causes no flicker, such as a DC lighting lamp. KP-M1A - 24 -...
  • Page 25: Connection

    11. Connection Connection of options KP-M1A Coaxial cable Image processor Connect either of the cables. Video monitor Coaxial cable Camera cable JUNCTION BOX AC adaptor (Option) JU-M1A AP-130 +12V When not using the AP-130, supply 12V from the rear of the Junction box.
  • Page 26: Optical System

    Reinstall and secure filter holder (2) with two screws (1). Caution Prior to removing the optical filter, be sure to turn off the power. IR cut filter IRC650 Dimensions: 14 x 12 x 1.0t Part code: XMD0006 KP-M1A - 26 -...
  • Page 27: Composition

    2)Operation manual 14. External view 15. Optional accessories 1)Tripod adapter, TA-M1 2)12-pin plug, HR10A-10P-12S(01) 3)Junction box, JU-M1A 4)Dummy glass, ARC1214 5)Camera cables Mould Type Assembly Type Shield Type C-201KSM C-201KS C-201KSS C-501KSM C-501KS C-501KSS C-102KSM C-102KS C-102KSS KP-M1A - 27 -...
  • Page 28 B, using four supplied screws(M2x5). Note: If the screws are too long, they will cause trouble to the camera. Be sure to check the length before use. 2) 12-pin plug HR10A-10P-12S(01) Product code: 23810AX 3) Junction box JU-M1A KP-M1A - 28 -...
  • Page 29 Mould type Assy type Shielded type C-201KSM C-201KS C-201KSS (23861AX) (23856AX) (23872AX) C-501KSM C-501KS C-501KSS (23862AX) (23857AX) (23873AX) C-102KSM C-102KS C-102KSS (23863AX) (23858AX) (23874AX) Specify assembly or shielded type at time of order. ( ): Product code KP-M1A - 29 -...
  • Page 30 Characteristic impedance is kept at constant even at cable length change. Cable Attenuation at 4MHz Attenuation at 7MHz length 50dB/Km 70dB/Km 0.05 0.07 Attenuation due 0.14 to cable length(dB) 0.25 0.35 The video bandwidth obtained by the KP-M1A is up to approximately 7MHz. KP-M1A - 30 -...
  • Page 31: Notes To Users

    Auto electric shutter In regions using 50 Hz power line frequency , flicker can appear on the monitor screen from light sources such as fluorescent or mercury. In such cases , release the auto electronic shutter. KP-M1A - 31 -...
  • Page 32 When fine patterns are shot , moire may be displayed. " The CE mark is required when exporting to Europe. Obtain the necessary authorization for the customer’s system. Enclose the camera in a shielded case and use shielded cable. KP-M1A - 32 -...
  • Page 33: Attachment Spectral Sensitivity Characteristic

    Spectral sensitivity (typical example) KP-M1A - 33 -...
  • Page 34 , and the cost is changed to a customer. (3) Hitachi Kokusai Electronic is not liable for the losses caused when the equipment is used in a system used for business trades , production process , medical fields , crime prevention applications , etc.

Table of Contents