Construction Access Mode is used to allow access before the lock
has been programmed, and for testing purposes.
• Enabled by default.
• The lock will remain in Construction Access Mode until the mode
is cancelled as described below.
• No audits are captured while the lock is in Construction Access
Mode.
Create the Master Construction Credential - Locks with
Card Readers
!
The first card presented to a new lock automatically becomes
the Master Construction Credential!
After you have created the Master Construction Credential, you can
then use that card to add construction access mode user credentials.
ÎThe Master Construction Credential will not grant access. It is used
only to add additional credentials.

Add User Credentials - Locks with Card Readers

1. Present the Master Construction Credential to the lock. The
Schlage button will light green.
2. Present the user credential to be added within twenty (20) seconds. The user credential will be
added to the lock database.
ÎCredentials added using the Master Construction Credential will have normal 24/7 access.

Cancel Construction Access Mode

Do one of the following:
• Authenticate or program the lock with the Handheld Device. See the Schlage Utility Software User
Guide for more information.
• Reset the lock to factory settings. See Resetting to Factory Default Settings on page 9 for more
information.
• Establish first successful communication with the host (ACP). See Lock Address Setup on page 8
for more information.
!
When construction access mode is cancelled, the Master Construction Credential and all
other credentials added using the Master Construction Credential will no longer function.

CONSTRUCTION ACCESS MODE

AD-300 Networked Hardwired Lock User Guide
5
TIPS
Use the same Master
Construction Credential for
all the locks in the facility.
If you present the first card
to a new lock to create
the Master Construction
Credential and the card is
not accepted, the lock has
either been programmed
or already has a Master
Construction Credential.
If the Master Construction
Credential cannot be
located, or to put the lock
back into construction
access mode, reset the
lock to factory settings. See
Resetting to Factory Default
Settings on page 9 for more
information.