Safety Instructions; Using The Remote Control Unit; Installation Location - Technibel MPA9FIB0R5I Operating Instructions Manual

Technibel mpa9fib0r5i; mpafia0r5i; mta8fia0r5i; mta8fbia0r5i; mtafia0r5i; mtafbia0r5i; k2fafia0r5i; k2fafib0r5i; kpa8fia0r5i; kpa9fib0r5i; ca8fia0r5i; ca9fib0r5i; ca10ficr5i; sda8fia0r5i; sda9fib0r5i; dsa10ficr5i split type air conditioners
Hide thumbs Also See for MPA9FIB0R5I:
Table of Contents

Advertisement

INSTALLATION LOCATION

We recommend this air conditioner to be installed
properly by qualified installation technicians in
accordance with the installation instructions provided
with the unit.
WARNING
Do not install this air conditioner where there are
fumes or flammable gases, or in an extremely humid
space such as a green house.
Do not install the air conditioner where excessively
EG
high heat-generating objects are placed.
Do not install the air conditioner where the
atmosphere is extremely damp or humid (e.g.
greenhouse or laundry) it could be wetted by drops
of water (i.e. in laundries).
To protect the air conditioner from heavy corrosion,
avoid installing the outdoor unit where salty sea
water can splash directly onto it or in sulphurous air
near a spa.
ELETRICAL REQUIREMENTS
Before installation, check that the voltage of the electric
supply in your home or office is the same as the voltage
shown on the nameplate.
All wiring must conform to the local electrical codes.
Consult your dealer or a qualified electrician for details.
Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring.
Wiring must be done by a qualified electrician.

SAFETY INSTRUCTIONS

Read this booklet carefully before using this air
conditioner. If you still have any difficulties or
problems, consult your dealer for help.
This air conditioner is designed to give you
comfortable room conditions. Use this only for its
intended purpose as described in this Instruction
Manual.
WARNING
Never use or store gasoline or other flammable vapor or
liquid near the air conditioner. It is very dangerous.
Never install electrical equipment, which is not
protected with IPX1 protection (protection against
vertical water drop), under the unit.
The manufacturer assumes no responsabilities if the
safety regulations or local codes are not observed.
CAUTION
Never use the power main switch to start or stop the
air conditioner: always use the ON/OFF button on the
remote control unit or the selector switch on the unit.
For your safety care check periodically the conditions
of the electric supply cable; the electrical connection
of the unit is Y type with cable prepared in a special
way; in case you should notice any damage due to
usage, call the nearest After Sale Service to get the
cable replaced.
Do not let children play with the air conditioner.
Do not cool the room too much if babies or invalids
are present.
This air conditioner is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the air conditioner
by a person responsible for their safety.

USING THE REMOTE CONTROL UNIT

HOW TO INSTALL BATTERIES
Remove trhe lid in the rear part of the remote control unit
and check the settings of the four microswitches as
shown below:
SWITCHES
Insert two AAA alkaline batteries of 1,5 V-DC making
sure that point in the direction marked in the battery
compartment.The displayed time flashes.
Press the SEL TYPE button.
Remote controller is now ready for operation.
The batteries last average more than six months, anyway
it depends on how much you use the remote control
unit.
Remove the batteries if you do not use the remote control
unit for more than one month.
Replace the batteries when the remote control unit lamp
fails to light, or when the air conditioner does not receive
the remote control unit signals.
The batteries of the remote control contain polluted
substances. Exhausted batteries must be disposed
according to the laws in force.
ONLY IF YOU INSTALL MORE THAN ONE
NOTE
INDOOR UNIT IN THE SAME ROOM
Set unit A, B, C or D with Remote Control (see procedure
in Installation Manual of Outdoor Unit).
TEMPERATURE SENSOR SELECTOR
Under normal conditions the room temperature is detected
and checked by the temperature sensor placed in the
remote controller (I FEEL icon displayed ).This function
is designed to provide a comfortable room temperature
by transmitting the temperature control command from the
location next to you. When using this function, the remote,
control should always be pointed at the air conditioner,
therefore it should be placed in a position in which it is
visible by the indoor unit (for example, do not put it in a
drawer).
It is possible to disable the remote controller room sensor
pressing the I FEEL button. In this case the I FEEL icon
on the remote controller display lights off and only the
sensor placed in the air conditioner becomes active.
NOTE
The remote control unit transmits signals to the indoor
unit each time you press a key and at any temperature
change detected by the IFEEL sensor. In case of
troubles (low batteries, remote control placed in a
position not visible by the indoor unit,...) room
temperature control is automatically switched to the
sensor of the indoor unit. In this case, the temperature
around the remote control unit may differ from the
temperature detected in the air conditioner position.
OPERATION WITH THE REMOTE CONTROL UNIT
When using the remote control unit, always point the unit
transmitter head directly at the air conditioner receiver.
HOW TO TURN ON THE AIR CONDITIONER
Press the ON/OFF button to turn the air conditioner on.
The operation lamp will light up, indicating the unit is in
operation.
6
PLEASE, SEE THE END
OF THIS MANUAL FOR
DETAILS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents