Technibel MTA8FIA0R5I Series Operating Instructions Manual

Technibel mta8fia0r5i series; mta8fbi0r5i series; mtafia0r5i series; mtafbi0r5i series; kpa8fia0r5i series; ca8fia0r5i series; sda8fia0r5i series air conditioners
Hide thumbs Also See for MTA8FIA0R5I Series:

Advertisement

Quick Links

OPERATING INSTRUCTIONS • ISTRUZIONI D'USO
NOTICE D'UTILISATION • BEDIENUNGSANLEITUNG
MONO SPLIT
MTA8FIA0R5I--
MTA8FBI0R5I--
MONO/MULTI SPLIT
KPA8FIA0R5I--
MONO/MULTI SPLIT
CA8FIA0R5I--
Split air conditioner system • Condizionatore d'aria split system
Acondicionador de aire de consola partida sistema split •
ΔΙΑΙΡΟΥΜΕΝΕΣ ΜΟΝΑΔΕΣ ΚΛΙΜΑΣΜΟΥ
INSTRUCCIONES DE USO
MONO/MULTI SPLIT
SDA8FIA0R5I--
Climatiseurs split • Split-klimagerät
37.4254.033.01
10/2010
MULTI SPLIT
MTAFIA0R5I--
MTAFBI0R5I--
EG
I
F
D
E

Advertisement

Table of Contents
loading

Summary of Contents for Technibel MTA8FIA0R5I Series

  • Page 1 OPERATING INSTRUCTIONS • ISTRUZIONI D’USO NOTICE D’UTILISATION • BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO MONO SPLIT MULTI SPLIT MTA8FIA0R5I-- MTAFIA0R5I-- MTA8FBI0R5I-- MTAFBI0R5I-- MONO/MULTI SPLIT KPA8FIA0R5I-- MONO/MULTI SPLIT SDA8FIA0R5I-- MONO/MULTI SPLIT CA8FIA0R5I-- Split air conditioner system • Condizionatore d’aria split system Climatiseurs split • Split-klimagerät Acondicionador de aire de consola partida sistema split •...
  • Page 2: Table Of Contents

    CONTENTS NAME OF PARTS AND OPERATION SELECTOR SWITCH INSTALLATION LOCATION ELECTRICAL REQUIREMENTS SAFETY INSTRUCTIONS USING THE REMOTE CONTROL UNIT REMOTE CONTROL UNIT HOW TO SET THE PRESENT TIME COOLING HEATING AUTOMATIC OPERATION DEHUMIDIFYING (DRY) FAN ONLY ADJUSTING THE FAN SPEED FILTER Ti0 NIGHT MODE/ENERGY SAVING HIGH POWER MODE...
  • Page 3: Name Of Parts And Operation Selector Switch

    NAME OF PARTS AND OPERATION SELECTOR SWITCH 1. Remote control unit. 2. Remote control sensor: Detects the room temperature NOTES around the remote control unit, the air conditioner is It is possible to set the air conditioner in order to let ●...
  • Page 4 1. Remote control unit. 2. Remote control sensor: Detects the room temperature around the remote control unit, the air conditioner is controlled accordingly. 3. Air outlet: Conditioned air is blown out of the air conditioner through the air outlet. 4. Air intake: Air from the room is drawn into this section and passes through air filter which removes dust.
  • Page 5: Installation Location

    INSTALLATION LOCATION USING THE REMOTE CONTROL UNIT HOW TO INSTALL BATTERIES We recommend this air conditioner to be installed ● properly by qualified installation technicians in Remove trhe lid in the rear part of the remote control unit ● accordance with the installation instructions provided and check the settings of the four microswitches as with the unit.
  • Page 6: Cooling

    REMOTE CONTROL UNIT DISPLAY I FEEL mode is active Information is displayed when the remote controller is switched on. (remote controller If switched off, only the operating mode, the room temperature and sensor active) the clock are shown Filter Ti0 is ON Operation mode Room...
  • Page 7: How To Set The Present Time

    HOW TO SET THE PRESENT TIME HEATING PERFORMANCE A heat pump conditioner heats a room by taking heat from 1. Press the button SEL TYPE three times. outside air. The heating efficiency will fall off when the The time indication alone flashes. outdoor temperature is very low.
  • Page 8: Adjusting The Fan Speed

    NOTE FILTER Ti0 (if present) Use DRY operation when you want to reduce the humidity ● in the room. Pressing the FILTER button (symbol on the display) ● Once the room temperature reaches the set level, the unit the filtering system with titanium dioxide is activated; this repeats the cycle of turning on and off automatically.
  • Page 9: Setting The Timer

    SETTING THE TIMER ADJUSTING THE AIR FLOW DIRECTION A) HOW TO SET THE ON TIME HORIZONTAL (manual) Only for AWI-FCI models 1. Press the SEL TYPE button once. The horizontal air flow can be adjusted by moving the The ON and time indications flash. vertical vanes to the left or right, as indicated in the following 2.
  • Page 10 The functional flap automatically closes when ● HOW TO ADJUST THE FLAP DIRECTION NOTES the unit is off. The aesthetic flap automatically closes 3 ● AWI MODELS minutes after the unit is switched off. (ONLY FOR AWI MODELS) When the unit starts in heating operation, ●...
  • Page 11: Operation Without The Remote Control Unit

    CARE AND CLEANING OPERATION WITHOUT THE REMOTE CONTROL UNIT WARNING If you have lost the remote control unit or it has troubles, follow the steps below. Maintenance operations must be carried out by specially ● trained personnel. 1. WHEN THE AIR CONDITIONER IS STOPPED ●...
  • Page 12 Washing the grille with water AIR FILTER ● Clean the grille gently using a soft sponge, or the like. AWI-FCI MODELS Then wipe away any remaining moisture. ● Neutral detergent may be used to remove stubborn The filter behind thefront panel should be checked and dirt.
  • Page 13 1.Remove the screw on each side out of the latch using a REPLACEMENT OF ACTIVATED CARBON AIR screwdriver. FILTER 2.Press on the two latches of the air intake grille with your The filter is disposable. ● thumbs in the direction of the arrow to open the grille. Do not throw away the filter frame.
  • Page 14 TROUBLESHOOTING WARNING ● The use of portable telephones near the air conditioner may cause disturbance to its normal operation and must be avoided. In case abnormal operation is noticed, (OPERATION lamp lights, but the air conditioner will not run) to restore normal operation turn-off electric supply for about 3 minutes, by disconnecting the main switch or the wall plug, then start again the air conditioner.
  • Page 15 HOW TO REMOVE BATTERIES Remove the lid. ● Press the battery toward the negative end and lift it out by its positive ● end (as shown in the figure). Remove the other battery in the same way. ● COME RIMUOVERE LE BATTERIE Rimuovere il coperchio.
  • Page 16 F-GAS Regulation (EC) No. 842/2006 Do not vent R410A into atmosphere: R410A is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975. Non disperdere R410A nell'atmosfera: R410A è un gas fluorinato a effetto serra, coperto dal protocollo di Kyoto, con potenziale di riscaldamento globale (GWP) = 1975.

Table of Contents