I Man Down Emergency Call
The man down emergency call function transmits an emergency
call automatically, after the transceiver laying down in a horizontal
position for a pre-set time period. (The optional UT-113
is required.)
UNIT
After the emergency call, the transceiver performs transmission and
reception alternately with the following conditions:
- Transmits the microphone signals.
- Receives the signal and emits audio.
When the emergency cancel code is received, the function is can-
celled.
IMPORTANT!: Set an emergency channel individually, to provide
certain emergency call operation is recommended.
I Emergency Call
The emergency call can be performed using the [Emergency Sin-
gle] or [Emergency Repeat] key (p. 11). The transceiver will send
an 5-tone, DTMF or MDC 1200 emergency command one time only
or repeatedly until receiving the control code.
The emergency call can be transmitted without a beep emission
and LCD indication change when the [Emergency Single (Silent)]
or [Emergency Repeat (Silent)] (p. 11) key is pushed.
The emergency transmission is performed on the emergency chan-
nel, however, when no emergency channel is specified, the signal is
transmitted on the previously selected channel.
Ask your dealer for details.