1) Replacement of the paper feed roller/storage roller/F/R mylar/feed roller pad
1
3
2
1
2
3
1
7
5
6
2
3
4
1
1
4
4
(1) Pull out the ADU until it stops.
(2) Remove the upper cover (2 screws).
(3) Lift the transport guides (1 and 2).
(1) Remove the screws (x 2).
(2) Remove the stopper plate.
(3) Remove the touch rings from the guide
3
plates.
(4) Disconnect the feed clutch connector.
(5) Remove the touch rings (x2).
6
(6) Move the bearing toward the feed rollers.
(7) Remove the paper feed roller shaft.
(1) Remove the touch ring.
(2) Remove all rollers by pulling in the arrow
direction.
(3) Replace the paper feed roller.
(4) Replace the storage rollers.
• Take off the F/R mylar (kit) and replace it.
Note: Perform step 7 first.
4-33