6) Replacement of the toner dispersion prevention cover/magnetic roller stopper
10
1
2
1
3
7) Replacement of the dust collecting filter
11
2
1
3
4
A
5
5
4-18
• Conduct procedure 1 and 2 then pull out
the developer unit.
(1)Remove the screws (x 2).
(2)Remove the toner dispersion prevention
cover.
(3)Remove the magnetic roller stoppers
(front/rear) and replace the magnetic
3
roller.
• Conduct procedure 1 and 2 then pull out
the drum unit
(1)Disconnect the sensor harness.
(2)Remove the touch ring.
(3)Slide the sensor base to rear side then
put it down and pull out.
(4)Remove the sensor PCB from under side.
(5)Push the
from under side and slide the
A
separation finger then remove it.
Note: Be careful when removing and
reinstalling the drum finger that the two
springs are not lost or damaged.
(6)Reassemble in reverse order.