23. Note the orientation of the power supply cooling shroud and install it into the chassis by inserting the
two small tabs
1
on the bottom of the shroud into the corresponding holes
Figure 170. Installing the power supply cooling shroud
24. Install the coin-cell battery on the new system board. See "Replacing the coin-cell battery" on page 196.
25. If you have a TMM Premium, install the TMM Premium on the new system board. See "Installing the
TMM Premium" on page 129.
26. If you have a TPM, install the TPM on the new system board. See "Installing the TPM" on page 132.
27. Install the two riser card assemblies on the new system board. See "Replacing the riser card assembly
1" on page 183 and "Replacing the riser card assembly 2" on page 185.
28. Note the orientation of the system fan cage. Align the left and right sides of the system fan cage with the
corresponding mounting posts in the chassis. Then, press the system fan cage with the installed system
fans straight down into the chassis until the system fan cage is correctly seated and the system fans are
correctly connected to the system fan connectors on the system board.
Figure 171. Installing the system fan cage with system fans
29. Install any other parts that you have removed and connect all cables to the new system board. Refer
to the information that you have recorded and the related topics in "Installing, removing, or replacing
hardware" on page 92.