8. Carefully position the new front panel board on the chassis so that the front controls, connectors,
and LEDs are through the corresponding holes in the front bezel and the two screw holes in the new
front panel board are aligned with the corresponding mounting studs on the chassis. Then, install the
screws to secure the front panel board in place.
Figure 151. Installing the front panel board for server models with eight 3.5-inch hard-disk-drive bays
9. Connect the front panel cable and the front panel USB cable to the rear of the new front panel board.
10. If you are instructed to return the old front panel board, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to "Completing the parts replacement" on page 206.
Replacing the front panel board for server models with 2.5-inch hard-disk-drive bays
Attention: Do not open your server or attempt any repair before reading and understanding "Safety information"
on page iii and "Guidelines" on page 87.
To replace the front panel board for server models with 2.5-inch hard-disk-drive bays, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the Rack Installation Instructions that comes with the server.
3. Remove the server cover. See "Removing the server cover" on page 89.
4. Remove the front bezel. See "Removing and reinstalling the front bezel" on page 91.
5. Remove the cooling shroud. See "Removing and reinstalling the cooling shroud" on page 97.
6. Locate the front panel board. See "Components of server models with 2.5-inch hard-disk-drive bays"
on page 37.
7. Remove the left cage. See "Removing and reinstalling the left cage" on page 99.
.