5. Ensure that the cover latch is in the open position. Place the server cover above the chassis so that
the cover latch is aligned with the cover latch slot in the chassis. Then, lower the server cover onto
the chassis until the cover latch is inserted into its slot and both sides of the server cover engage the
guides on both sides of the chassis.
Figure 173. Installing the server cover
6. Pivot the cover latch
same time until the server cover snaps into position and the cover latch is closed.
Figure 174. Closing the server cover completely
7. Install the server into a rack cabinet using the rail kit that comes with the server. See the Rack Installation
Instructions that comes with the server.
8. Reconnect external cables and power cords to the server. See "Rear view of the server" on page 29 to
identify the connectors on the rear panel of the server.
208
ThinkServer RD440 User Guide and Hardware Maintenance Manual