8. Carefully lift the backplane straight up slightly so that the small hooks
with the corresponding holes in the backplane. Then, slowly and carefully move the backplane to the
rear of the chassis until the hooks
remove the backplane out of the chassis.
Figure 139. Removing the backplane for server models with eight 3.5-inch hard-disk-drive bays
9. Touch the static-protective package that contains the new hot-swap hard-disk-drive backplane to any
unpainted surface on the outside of the server. Then, remove the new backplane from the package.
Note: Carefully handle the backplane by its edges.
10. Note the orientation of the new backplane and position it on the chassis so that the small hooks
the chassis pass through the corresponding holes in the new backplane. Then, carefully press the new
backplane straight down so that it is secured in place by the small retaining studs
Figure 140. Installing the backplane for server models with eight 3.5-inch hard-disk-drive bays