SECTION 7
DESCR/OPERATION
7.8
TRANSICOIL ELECTRONIC MODULE INSTRUMENT SYSTEM
(EMIS) (CONT'D)
After the self-test is complete, the EDI will automatically display the
MAP, RPM, TIT, FF and OAT in the LCD windows. NOTE: Any exceedances
that have previously been recorded must be called up manually by the operator.
To post the digital reading of a different analog instrument, momentarily
press the select button adjacent to that analog indicator. The selected analog
indicator will have it's "GREEN" status light illuminated. The left and right
analog indicators can only be posted in their corresponding middle left and
middle right EDI digital displays. The EDI digital display can be "blanked" at
the operators discretion by pressing the "BLK" button located on the EDI
display unit. To exit this mode, select any analog indicator from the EMIS
system stack or select any other function (fuel management, % power, etc.)
Since the push button designated for blanking
the display has secondary functions during the
limitation exceedance review, fuel management
mode and fuel loading mode, the display
blanking function is disabled during these
modes of operation.
If an exceedance occurs, the blank mode will end
and the exceedance will automatically be posted.
Prior to engine start, a new fuel loading can be entered into the EDI by
selecting the fuel posting mode. This is done by pressing the "S" button on the
left side of the display. Once in the fuel posting mode, enter the fuel loading
mode by simultaneously pressing the "S" and "Up Arrow" buttons (Figure 7-15
and 7-17). The digital display will show "000" or present fuel remaining with
the left most digit flashing.
the flashing digit up while the "DOWN ARROW" will increment the flashing
digit down. Pressing "T" button will toggle between flashing parameter digits.
This sequence is repeated until the new fuel loading is displayed in the EDI
window. To enter this fuel load into memory, depress the "S" button on the left
side of the display. At this point the EDI will return to the fuel posting mode
automatically.
REPORT: VB-1710
7-12
Note:
Note:
Pressing the "UP ARROW" button will increment
ISSUED: FEBRUARY 23, 1999
PA-46-350P, MALIBU