Venting; Approved Vent Systems; Restrictor Assembly And Installation; Venting For Horizontal Terminations - kozy heat Slayton 42S Installation And Operation Manual

Direct vent linear fireplace
Hide thumbs Also See for Slayton 42S:
Table of Contents

Advertisement

11.0

VENTING

Consult the local and national installation codes to assure adequate combustion and ventilation air is available. Flame height and
appearance will vary depending upon venting configuration and the type of fuel used.
11.1

Approved Vent Systems

This fireplace is designed to be used with any of the following vent systems without the use of an additional adaptor.
Refer to the vent manufacturer's installation manual for complete installation instructions. Installation must conform with
venting requirements and restrictions as outlined in this manual.
Provide a means for visually checking the vent connection to the appliance after the fireplace is installed.
Venting Manufacturers
American Metal Products
BDM
ICC
Kozy Heat
Metal Fab
RLH
Security
Selkirk
Simpson Dura-Vent
11.2
Restrictor Assembly Installation
Each installation is unique and affected by various factors
including venting configuration, altitude and climate.
Therefore, after fireplace installation is complete, a
restrictor (included with fireplace components packet)
may be required or may need to be removed or modified.
Please refer to Figure 11.1 for installation instructions if
installing the restrictor in conjunction with venting. A
restrictor may be used to achieve desired flame
appearance on any venting configuration with 6 ft. (1.83
m) of vertical pipe or more.
18.3 Restrictors, on page 43, outlines restrictor
recommendations depending on burner flame
appearance and instructions on installation after venting
is completed.
11.3

Venting for Horizontal Terminations

11.3.1
Horizontal Vent Section Clearances
Vent Pipe Surface Clearances
Table 11.1, Approved Vent systems
Approved Vent System Products
8" x 5" Direct Vent Chimney System, Model Ameri-Vent
8" x 5" Direct Vent Chimney System
8" x 5" Direct Vent Chimney System, EXCELDirect
#800 Series Flexible Vent System
8" x 5" Direct Vent Chimney System,
8" x 5" Direct Vent Chimney System
8" x 5" Direct Vent Chimney System
8" x 5" Direct Vent Chimney System, Model Direct Temp
DV-PRO 8" x 5" Direct Vent Systems
Table 11.2, All Approved Vent Systems, Clearances to Combustible Material
Top
1 in. (25 mm)
IMPORTANT
Figure 11.1, Restrictor Assembly and Installation Instructions
Large Restrictor
Slide restrictor into exhaust pipe on top of fireplace with tabs
pointing towards you prior to attaching venting.
Bottom
1 in. (25 mm)
18
Horizontal
Termination
X
X
X
X
X
X
X
X
Bend tabs to approx. 80
Remove tab(s) to
degree angles to create
create small restrictor
tension to hold itself in place
when installed.
Sides
1 in. (25 mm)
Vertical
Termination
X
X
X
X
X
X
X
X

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slayton 42s sla-42s

Table of Contents